Wolf ICBCT15G LT I P L E C O O K to P I N S TA L L AT I O N, T I O N a L S TA L L AT I O N S

Page 11

I N S TA L L AT I O N I N S T RU C T I O N S

I N S TA L L AT I O N O P T I O N S

M U LT I P L E C O O K TO P I N S TA L L AT I O N

If the gas cooktop is to be used with any combination of additional cooktop units or modules with a filler strip, the cut-out width is calculated by adding the corresponding units' cut-out dimensions plus 32 mm for each addi- tional unit. Refer to the illustration below.

IMPORTANT NOTE: When multiple units are installed side by side, each unit must have its own separate recommended electrical circuit.

When two or more modules are installed together, an integrated module filler strip (IFILLER/S) is recommended. Contact your Wolf dealer for information on these accessory components.

1518 mm – FOUR MODULES WIDTH OR

1511 mm – 762 mm COOKTOP AND TWO MODULES OR

1276 mm – 914 mm COOKTOP AND ONE MODULE

1130 mm – THREE MODULES WIDTH OR 1124 mm – 762 mm COOKTOP AND ONE MODULE

743 mm

TWO MODULES WIDTH

 

 

 

 

 

356 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

489 mm

64 mm

 

 

CUT-OUT

 

 

CUT-OUT

 

 

 

 

 

WIDTH

 

 

DEPTH

min

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FRONT OF COUNTERTOP

Countertop cut-out dimensions for installation of multiple cooktops

O P T I O N A L

I N S TA L L AT I O N S

Dimensions will vary according to the specific installa- tion.

11

Image 11
Contents GAS Cooktops Page G L I S H P Ã N O L A N Ç a I S TA L I a N O U T S C H N TAC T F O R M AT I O N S TA L L AT I O N R E Q U I R E M E N T S Wolf G a S C O O K to P SRating Plate Information Location Requirements Countertop CUT- OUT DimensionsS TA L L AT I O N I N S T RU C T I O N S F O R E YOU Start T E PreparationS TA L L AT I O N S P E C I F I C AT I O N S Installation Specifications Model ICBCT15GModel ICBCT15G Dimensions Wolf GA S CO O K to P SOverall Width 762 mm Overall Height 102 mm Installation Specifications Model ICBCT30GModel ICBCT30G Dimensions S TA L L AT I O N I N S T RU C T I O N SOverall Width 914 mm Overall Height 102 mm Wolf GA S CO O K to P S S TA L LAT I on SpecificationsInstallation Specifications Model ICBCT36G Model ICBCT36G DimensionsT I O N a L S TA L L AT I O N S LT I P L E C O O K to P I N S TA L L AT I O NWolf GA S CO O K to P S GA S S U P P LY Requirements Electrical Shock Hazard Wiring DiagramE C T R I C a L R E Q U I R E M E N T S Recommended Ground MethodWolf GA S CO O K to P S Cooktop I N S TA L L AT I O N GAS Leak TestingO U B L E Shooting Initial LightingCO O K to P Removal If YOU Need S E RV I C E Model ICBCT30G R I N G D I AG R a M SF O R M AC I Ó N DE Contacto PrecauciónNota Importante Información DE LA Placa DE Datos T E S DE ComenzarRequisitos DE Ubicación Dimensiones DE Corte DE LA EncimeraInstrucciones DE I N S TA L a C I Ó N Preparación DEL S I T I OModelo ICBCT15G Medidas LA C a S D E GA S DE WolfEspecificaciones DE LA I N S TA L a C I Ó N Especificaciones DE LA Instalación Modelo ICBCT15GAnchura total 762 mm Altura total 102 mm Especificaciones DE LA Instalación Modelo ICBCT30GModelo ICBCT30G Medidas Anchura total 914 mm Altura total 102 mm Especificaciones DE LA I N S TA LA C I Ó NEspecificaciones DE LA Instalación Modelo ICBCT36G Modelo ICBCT36G MedidasInstalaciones Opcionales Instalación DE Varias Superficies DE CocciónSuministro D E GA S Nota ImportanteCuadro DE Conexiones Método DE Conexión a Tierra RecomendadoPrueba DE Fuga DE GAS LA C a S D E GA S DE Wolf S TA L a C I Ó N DE LA PlacaSolución DE P R O B L E M a S Encendido InicialExtracción DE LA P L a C a SI Necesita a S I S T E N C I a T É C N I C a Modelo ICBCT36G N TAC T ’ I N S TA L L AT I O N LA Q U E S D E C U I S S on AU GA Z WolfExigences Relatives a A N T DE Commencer InformationsPreparation DE L’ E M P LA C E M E N T Dimensions DE LA Decoupe DU Plan DE TravailExigences Relatives a L’EMPLACEMENT S T RU C T I O N S D ’ I N S TA L L AT I O NE C I F I C AT I O N S D ’ I N S TA L L AT I O N Specifications D’INSTALLATION Modele ICBCT15GModele ICBCT15G Dimensions LA Q U E S D E C U I S S on AU GA Z WO L FModele ICBCT30G Dimensions Specifications D’INSTALLATION Modele ICBCT30GE C I F I C AT I O N S D ’ I N S TA L LAT I on Specifications D’INSTALLATION Modele ICBCT36GModele ICBCT36G Dimensions LA Q U E S D E C U I S S on a U GA Z WO L FOptions ’INSTALLATION Installation DE Plaques DE Cuisson MultiplesDébit DU GA Z M a R Q U E P O RTA N T EN F I G U R AT I O N D E ’ a L I M E N TAT I on E N GA ZSchema DE Cablage Methode DE Mise a LA Terre RecommandeeDetection DES Fuites DE GAZ DE CuissonDepistage DES PA N N E S Allumage InitialRetrait DE LA P LA Q U E D E C U I S S on LA Q U E S D E C U I S S on AU GA Z WO L F Modèle ICBCT36G F O R M a Z I O N PER I Contatti Cosa Fare SE SI Sente Odore DI GAS I M a DI Iniziare A N I COT T U R a a GA S WolfInformazioni SULL’ETICHETTA Identificativa Requisiti PER L’UBICAZIONE Dimensioni Sfinestratura Piano DI LavoroIstruzioni PER L’ I N S TA L LA Z I O N E DEL S I toPagina Specifiche PER L’INSTALLAZIONE Modello ICBCT15GModello ICBCT15G Dimensioni ICBCT15GModello ICBCT30G Dimensioni Specifiche PER L’INSTALLAZIONE Modello ICBCT30GModello ICBCT36G Dimensioni Specifiche PER L’INSTALLAZIONE Modello ICBCT36GInstallazioni Opzionali Installazione CON PIÙ Piani DI CotturaPericolo DI Esplosione Portata GA SMetodo DI Messa a Terra Consigliato Schema ElettricoVerifica DI Eventuali Perdite DI GAS CotturaSoluzione DEI P R O B L E M Illuminazione InizialeRimozione DEL P I a N O D I COT T U R a SE È Necessaria a S S I S T E N Z a Modello ICBCT36G Vorsicht KO N TA K T F O R M AT I O N E NS K O C H M U L D E N VON Wolf Stallatio Nsvoraussetzungen Wichtiger HinweisVO R D E R I N B E T R I E B N a H M E F O R M AT I O NEN AUF DEM TypenschildGaskochmulden VON Wolf Stallatio Nsvoraussetzungen VO R DER Inbetriebnahme VO RB ER EIT UNG DES INSTALLATIONS- OrtesVoraussetzungen FÜR DEN Installationsort S TA L L AT I O N S AnweisungenDie nachstehenden Abbildungen enthalten die Installationsspezifikationen Modell ICBCT15GGaskochmulden VON Wolf S TA L L AT I O N S Spezifikationen Abmessungen FÜR Modell ICBCT15GGesamthöhe 102 mm Installationsspezifikationen Modell ICBCT30GAbmessungen FÜR Modell ICBCT30G Gesamtbreite 762 mmAbmessungen Installations SpezifikationenInstallationsspezifikationen Modell ICBCT36G Gaskochmulden VON WolfT I O N a L E S TA L L AT I O N E N S TA L L AT I O N VO N M E H R E R E N KO C H M U L D E NGasnennleistung Wichtiger HinweisVoraussetzungen FÜR DIE S V E R S O R G U N GStromschlaggefahr VerdrahtungsdiagrammS TA L L AT I O N S Anweisungen E K T R OVO R Aussetzungen Empfohlene ErdungsmethodeTesten AUF Gaslecks Gaskochmulden VON Wolf S TA L L AT I O N D E R KochmuldeH L E R S U C H E S TA L L AT I O N S Anweisungen E R F L Ä C H E N BrennerErstmaliges Anzünden Ausbauen DER K O C H M U L D EWenn S E R V I C E Erforderlich IST Modell ICBCT36G Wolf APPLIANCE, INC

ICBCT15G specifications

The Wolf ICBCT15G is a state-of-the-art infrared heating appliance that is primarily utilized in various residential and commercial heating applications. Known for its sleek design and innovative technology, the ICBCT15G is engineered to deliver exceptional energy efficiency while providing reliable warmth in any environment.

A standout feature of the Wolf ICBCT15G is its advanced infrared heating technology. Unlike traditional convection heaters that warm the air, infrared heaters directly warm the objects and surfaces in a room. This results in faster heating times and reduced energy consumption, making it an environmentally friendly option. The ICBCT15G efficiently converts electricity into infrared radiation, ensuring heat is distributed evenly and quickly throughout the space.

Another significant characteristic of the ICBCT15G is its smart control capabilities. It is equipped with a user-friendly digital interface that allows users to adjust temperature settings and heating schedules with ease. Additionally, the appliance can be integrated into smart home systems, enabling remote operation via mobile apps. This feature enhances user convenience and encourages energy-saving practices by allowing the unit to be scheduled to operate only when needed.

The ICBCT15G also boasts a compact and lightweight design, making it easy to install and relocate as needed. It can be mounted on walls or ceilings, providing flexibility in placement while maximizing floor space. The unit's modern aesthetic ensures that it seamlessly blends into any decor, making it an attractive addition to any home or office.

Safety features are paramount in the design of the Wolf ICBCT15G. It is equipped with advanced overheating protection, ensuring that the appliance automatically shuts off if it exceeds safe temperature limits. Additionally, the heater features a cool-touch surface, minimizing the risk of burns, which is particularly valuable in environments with children or pets.

In conclusion, the Wolf ICBCT15G is a powerful and efficient infrared heating solution that stands out due to its innovative technology, user-friendly controls, attractive design, and comprehensive safety features. Ideal for a wide range of applications, it provides not only warmth but also energy savings and convenience, making it a top choice for those seeking a reliable heating solution.