KitchenAid LI3Y7C, W10322991C installation instructions Venting Requirements

Page 5

Cabinet Dimensions

7¹⁄₄" (18.4 cm)

2" (5.1 cm) min. 6" (15.2 cm) min.*

6⁵⁄₈" (16.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent and power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7³⁄₈" (18.8 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply cable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

entry location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15" (38.1 cm)

 

Side

 

 

 

 

 

 

 

 

Side

 

cabinet

 

 

 

 

 

 

 

 

cabinet

 

 

 

 

 

30" (76.2 cm) or

 

 

 

 

 

 

 

 

 

 

36" (91.4 CM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“X” bottom of canopy to cooking surface

Centerline

Cooking surface

*For non-vented (recirculating) installations

IMPORTANT:

Minimum distance “X”: 24" (61.0 cm) from electric cooking surface.

Minimum distance “X”: 27" (68.6 cm) from gas cooking surfaces.

Suggested maximum distance “X”: 36" (91.4 cm)

The chimneys can be adjusted for different ceiling heights. See the following chart.

Vented Installations

 

Min. ceiling height

Max. ceiling height

 

 

 

Electric cooking

7' 5" (2.26 m)

9' 2" (2.79 m)

surface

 

 

Gas cooking

7' 8" (2.34 m)

9' 2" (2.79 m)

surface

 

 

 

Non-vented (recirculating) Installations

 

 

 

 

Min. ceiling height

Max. ceiling height

 

 

 

Electric cooking

7' 5" (2.26 m)

9' 6" (2.9 m)

surface

 

 

Gas cooking

7' 8" (2.34 m)

9' 6" (2.9 m)

surface

 

 

 

 

 

*NOTE: The range hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the range hood and the cooking surface. For higher ceilings, a Stainless Steel Chimney Extension Kit Part Number W10337357 is available from your dealer or an authorized parts distributor. The chimney extension replaces the upper chimney shipped with the range hood.

Venting Requirements

(vented models only)

Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap has a damper, do not use the damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale.

Consult your HVAC professional for specific requirements in your area.

Venting Methods

This canopy hood is factory set for venting through the roof or wall.

A 6" (15.2 cm) round vent system is needed for installation (not included). The hood exhaust opening is 6" (15.2 cm) round.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.

Vent system can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.

Rear discharge

A 90° elbow may be installed immediately above the hood.

5

Image 5 Contents
Canopy Range Hood Table DES Matières Range Hood SafetyImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Venting Requirements Prepare Location Installation InstructionsElectrical Requirements Range Hood Mounting Screws Installation Install Range HoodVent Cover Support Bracket Installation Complete PreparationFor non-vented recirculating installations only For vented installations onlyConnect Vent System Make Electrical ConnectionComplete Installation Install Vent CoversRange Hood Controls Range Hood USEOperating the light Operating the blowerNon-Vented recirculating Installation Filters CleaningRange Hood Care Exterior SurfacesAGC Wiring DiagramAccessories Assistance or ServiceU.S.A CanadaThis limited warranty does not cover Kitchenaid Ventilation WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA Hotte DE CuisinièreImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences d’emplacement Installation dans une région à climat froid Dimensions du placardExigences concernant l’évacuation Air dappointSpécifications électriques Décharge à Installation sans Travers le toit Travers le murDécharge par larrière Calcul de la longueur effective du circuit dévacuationPréparation de lemplacement Instructions DinstallationInstallation des vis de montage de la hotte Installation de la bride de cache-conduitRaccordement du circuit dévacuation Installation de la hotteRaccordement électrique Installation des cache-conduitsCommandes de la hotte de cuisinière Achever l’installationUtilisation DE LA Hotte Utilisation de la lampeNettoyage Entretien DE LA HotteOhms Schéma DE CâblageAu Canada Assistance OU ServiceAccessoires La présente garantie limitée ne couvre pas Garantie DU Système DE Ventilation KitchenaidAll rights reserved W10322991C