KitchenAid W10322991C, LI3Y7C Connect Vent System, Make Electrical Connection

Page 8

Connect Vent System

1.Install transition on top of hood (if removed for shipping) with 2 - 3.5 x 9.5 mm sheet metal screws.

A

B

A. Vent transition

B. 3.5 x 9.5 mm screw

For vented installations only:

1.Fit vent system over transition piece.

2.Seal connection with clamps.

3.Check that back draft dampers work properly.

For non-vented (recirculating) installations only:

1.Assemble the air deflector with the duct cover bracket with 2 assembly screws provided with the Recirculation Kit.

B A

2.Measure from the bottom of the air deflector to the bottom of the hood outlet.

 

A

B

 

X

C

D

 

E

 

A. Air deflector

B. Vent clamp

C. X = length to cut vent duct

D. Vent duct

E. Exhaust outlet

3.Cut the duct to the measured size (X).

4.Remove the air deflector.

5.Slide the duct onto the bottom of the air deflector.

6.Place the assembled air deflector and duct over the exhaust outlet from the hood.

7.Reassemble the air deflector to the duct cover bracket with 2 assembly screws.

8.Seal connections with vent clamps.

B

C

A. Vent cover bracket

B. 2.9 x 6.5 mm screws

C. Deflector

Make Electrical Connection

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Remove terminal box cover.

3.Remove the knockout in the terminal box and install a UL listed or CSA approved ¹⁄₂" strain relief.

8

Image 8 Contents
Canopy Range Hood Range Hood Safety Table DES MatièresImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Venting Requirements Prepare Location Installation InstructionsElectrical Requirements Install Range Hood Range Hood Mounting Screws InstallationVent Cover Support Bracket Installation Complete PreparationFor vented installations only For non-vented recirculating installations onlyConnect Vent System Make Electrical ConnectionInstall Vent Covers Complete InstallationRange Hood USE Range Hood ControlsOperating the light Operating the blowerCleaning Non-Vented recirculating Installation FiltersRange Hood Care Exterior SurfacesWiring Diagram AGCAssistance or Service AccessoriesU.S.A CanadaKitchenaid Ventilation Warranty This limited warranty does not coverSécurité DE LA Hotte DE Cuisinière Votre sécurité et celle des autres est très importanteImportantes Instructions DE Sécurité Outils et pièces Exigences DinstallationExigences d’emplacement Dimensions du placard Installation dans une région à climat froidExigences concernant l’évacuation Air dappointDécharge à Installation sans Travers le toit Travers le mur Spécifications électriquesDécharge par larrière Calcul de la longueur effective du circuit dévacuationInstructions Dinstallation Préparation de lemplacementInstallation des vis de montage de la hotte Installation de la bride de cache-conduitInstallation de la hotte Raccordement du circuit dévacuationInstallation des cache-conduits Raccordement électriqueAchever l’installation Commandes de la hotte de cuisinièreUtilisation DE LA Hotte Utilisation de la lampeEntretien DE LA Hotte NettoyageSchéma DE Câblage OhmsAu Canada Assistance OU ServiceAccessoires Garantie DU Système DE Ventilation Kitchenaid La présente garantie limitée ne couvre pasW10322991C All rights reserved