NOTE: If microwave oven does not need to be adjusted, skip steps 7-9.

7.If adjustment is required, rotate microwave oven downward. Using 2 or more people, lift microwave oven off of mounting plate, and set aside on a protected surface.

8.Loosen mounting plate screws. Adjust mounting plate and retighten screws.

9.Repeat steps 3-6.

10.With the microwave oven centered, and with at least one person holding it in place, insert bolts through upper cabinet into microwave oven. Tighten bolts until there is no gap between upper cabinet and microwave oven.

NOTES:

Some upper cabinets may require bolts longer or shorter than 3" (7.6 cm). Longer or shorter bolts are available at most hardware stores.

Overtightening bolts may warp the top of the microwave oven. To avoid warping, wood filler blocks may be added. The blocks must be the same thickness as the space between the upper cabinet bottom and the microwave oven.

A

A. Bolts

For Roof Venting Installation Only

1.Insert damper assembly through the cabinet cutout so that the long tab of the damper assembly slides under the raised tabs of the damper plate. Then secure with sheet metal screw.

NOTE: The screw cannot be installed if the damper assembly is not positioned as shown.

ABC

D EF

A. Raised tabs

B. Damper assembly

C. Sheet metal screw

D. Upper cabinet cutout

E. Long tab

F. Damper plate

2.Connect vent to damper assembly.

A B

A.Vent

B.Damper assembly (under vent)

Complete Installation

1.Refer to the Use and Care Guide for instructions on how to install filters into your model.

WARNING

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, fire, or electrical shock.

2.Plug microwave oven into grounded 3 prong outlet.

3.Reconnect power.

4.Check the operation of microwave oven by placing 1 cup (250 mL) of water on the turntable, and programming a cook time of 1 minute at 100% power. Test vent fan and exhaust by operating the vent fan.

5.If the microwave oven does not operate:

Check that a household fuse has not blown, or that a circuit breaker has not tripped. Replace the fuse or reset the circuit breaker. If the problem continues, call an electrician.

Check that the power supply cord is plugged into a grounded 3 prong outlet.

See the Use and Care Guide for troubleshooting information.

Installation is now complete.

Save Installation Instructions for future use.

10

Image 10
Contents Microwave Hood Combination Installation Instructions Microwave Hood Combination SafetyTools and Parts Installation RequirementsLocation Requirements Electrical Requirements Product DimensionsInstallation Dimensions RequiredRemove Mounting Plate Installation InstructionsWall Venting Installation Only Rotate Blower MotorRoof Venting Installation Only CD EPossible Wall Stud Configurations Locate Wall StudsInstallation for Wall Studs at Both Corner Holes Figure Installation for No Wall Studs at Corner Holes Figures 1Installation for Wall Stud at One Corner Hole Figure Mark Rear WallNo Wall Studs at Corner Holes Figures 1 Attach Mounting Plate to WallPrepare Upper Cabinet Wall Stud at One Corner Hole FigureFor Roof Venting Installation Only Install Damper AssemblyInstall the Microwave Oven C DComplete Installation Rectangular to Round Transition Venting Design SpecificationsFor optimal venting installation, we recommend Recommended Standard FittingsAccessories Replacement PartsAssistance Sécurité DE L’ENSEMBLE Four À MICRO­ONDES/HOTTE Exigences DinstallationOutillage et pièces Dimensions du produit Exigences demplacementDimensions à respecter lors de linstallation Dépose de la plaque de montage Instructions DinstallationSpécifications électriques Réorientation du moteur du ventilateurFixer la plaque de support du clapet avec la vis Configurations possibles du colombage mural Identifier la position du/des poteaux du colombage muralTracé sur le mur arrière Fixation de la plaque de montage sur le mur Perçage de trous dans le mur arrièreUn trou d’angle face à un poteau du colombage mural Figure Préparation du placard mural Installation du module du clapet anti­reflux Installation du four à micro-ondesAchever linstallation SPÉCIFICATIONS/CONCEPTION DU Circuit Dévacuation Raccords standard recommandésRaccord de transition rectangulaire/rond Pièces de rechange AccessoiresLongueur recommandée du circuit dévacuation Conduit de dia 15,2 cm = longueur totale 73 pi 22,2 m
Related manuals