Recommended Vent Length

A 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent should be used.

The total length of the vent system including straight vent, elbow(s), transitions and wall or roof caps must not exceed the equivalent of 140 ft (42.7 m) for either type of vent. See “Recommended Standard Fittings” section for equivalent lengths.

For best performance, use no more than three 90° elbows.

To calculate the length of the system you need, add the equivalent lengths of each vent piece used in the system. See the following examples:

3¹⁄₄" x 10" (8.3 x 25.4 cm) vent system = 73 ft (22.2 m) total

AB

6 ft (1.8 m)

2ft

(0.6 m)

C

A. One 3¹⁄₄" x 10" (8.3 x 25.4 cm) 90° elbow = 25 ft (7.6 m) B. 1 wall cap = 40 ft (12.2 m)

C. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

6" (15.2 cm) vent system = 73 ft (22.2 m) total

AB

6 ft (1.8 m)

2ft

(0.6 m)

CD

A. Two 90° elbows = 20 ft (6.1 m)

B. 1 wall cap = 40 ft (12.2 m)

C. 1 rectangular to round transition piece = 5 ft (1.5 m)

D. 2 ft (0.6 m) + 6 ft (1.8 m) straight = 8 ft (2.4 m)

If the existing vent is round, a rectangular to round transition piece must be used. In addition, a rectangular 3" (7.6 cm) extension vent between the damper assembly and rectangular to round transition piece must be installed to keep the damper from sticking.

ASSISTANCE

Call your authorized dealer or service center. When you call, you will need the microwave oven model number and serial number. Both numbers can be found on the model and serial number plate, which is located behind the microwave oven door on the front frame of the microwave oven.

If you need additional assistance, call us at our toll free number listed in the Use and Care Guide, or visit us on the Web.

Replacement Parts

If any of the installation hardware needs to be replaced, call us at our toll free number listed in the Use and Care Guide, and reference the appropriate part number listed here.

Damper Assembly

Mounting Screw Kit (includes

Part Number 8206442

parts A-F in “Parts Supplied” in

Mounting Plate

the “Tools and Parts” section)

Part Number W10110238

Part Number 8206315

 

Upper Cabinet Template

 

Part Number 8205927

 

Accessories

Filler Panel Kits are available from your dealer to use when installing this microwave oven in a 36" (91.4 cm) or 42" (106.7 cm) wide opening. The filler panels come in pairs. Each panel is

3" (7.6 cm) wide.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. Filler panels

Filler Panel Kit Number 8171336

White

8171337

Black

8171338

Biscuit

8171339

Stainless Steel

99403

 

Almond

See your authorized dealer or service center for details.

12

Image 12
Contents Microwave Hood Combination Installation Instructions Microwave Hood Combination SafetyInstallation Requirements Tools and PartsLocation Requirements Product Dimensions Installation DimensionsElectrical Requirements RequiredInstallation Instructions Wall Venting Installation OnlyRemove Mounting Plate Rotate Blower MotorRoof Venting Installation Only CD EPossible Wall Stud Configurations Locate Wall StudsInstallation for No Wall Studs at Corner Holes Figures 1 Installation for Wall Stud at One Corner Hole FigureInstallation for Wall Studs at Both Corner Holes Figure Mark Rear WallAttach Mounting Plate to Wall Prepare Upper CabinetNo Wall Studs at Corner Holes Figures 1 Wall Stud at One Corner Hole FigureInstall Damper Assembly Install the Microwave OvenFor Roof Venting Installation Only C DComplete Installation Venting Design Specifications For optimal venting installation, we recommendRectangular to Round Transition Recommended Standard FittingsReplacement Parts AccessoriesAssistance Exigences Dinstallation Sécurité DE L’ENSEMBLE Four À MICRO­ONDES/HOTTEOutillage et pièces Exigences demplacement Dimensions du produitDimensions à respecter lors de linstallation Instructions Dinstallation Spécifications électriquesDépose de la plaque de montage Réorientation du moteur du ventilateurFixer la plaque de support du clapet avec la vis Configurations possibles du colombage mural Identifier la position du/des poteaux du colombage muralTracé sur le mur arrière Perçage de trous dans le mur arrière Fixation de la plaque de montage sur le murUn trou d’angle face à un poteau du colombage mural Figure Préparation du placard mural Installation du module du clapet anti­reflux Installation du four à micro-ondesAchever linstallation Raccords standard recommandés SPÉCIFICATIONS/CONCEPTION DU Circuit DévacuationRaccord de transition rectangulaire/rond Accessoires Longueur recommandée du circuit dévacuationPièces de rechange Conduit de dia 15,2 cm = longueur totale 73 pi 22,2 m