5.Rotate blower motor end over end.

6.Rotate blower motor so that exhaust ports face the back of microwave oven, and lower blower motor back into the microwave oven.

A

A. Exhaust port

7.Reattach blower motor to back of microwave oven with 2 screws removed in Step 3.

8.Reattach damper plate. Make sure tabs at top and back of damper plate are inserted fully into their respective slots in the microwave oven.

A B CD E

A. Damper plate

B. Tabs at back of damper plate

C. Slots in back of microwave oven exterior

D. Damper plate tabs

E. Slots in top of microwave oven exterior

9. Secure damper plate with screw.

Roof Venting Installation Only

1.Repeat Step 1 from “Wall Venting Installation Only.”

2.Repeat Step 2 from “Wall Venting Installation Only.”

3.Repeat Step 3 from “Wall Venting Installation Only.”

4.Repeat Step 4 from “Wall Venting Installation Only.”

5.Rotate blower motor so that exhaust ports face the top of microwave oven, and flat sides of blower motor face back of microwave oven. Lower blower motor back into microwave oven.

A

A. Exhaust port

IMPORTANT: If blower motor is not positioned with flat sides facing the back of the microwave oven (as shown), performance will be poor.

6.Reattach blower motor to back of microwave oven with

2 screws removed in Step 3 of “Wall Venting Installation Only.” Securely tighten screws.

NOTE: If blower motor is not correctly oriented, the 2 screws removed in Step 3 cannot be reattached to the microwave oven.

7.Reattach damper plate. Make sure tabs at top and back of damper plate are inserted fully into their respective slots in the microwave oven.

A B CD E

A. Damper plate

B. Tabs at back of damper plate

C. Slots in back of microwave oven exterior

D. Damper plate tabs

E. Slots in top of microwave oven exterior

8. Secure damper plate with screw.

5

Image 5
Contents Microwave Hood Combination Safety Microwave Hood Combination Installation InstructionsLocation Requirements Installation RequirementsTools and Parts Installation Dimensions Product DimensionsElectrical Requirements RequiredWall Venting Installation Only Installation InstructionsRemove Mounting Plate Rotate Blower MotorCD E Roof Venting Installation OnlyLocate Wall Studs Possible Wall Stud ConfigurationsInstallation for Wall Stud at One Corner Hole Figure Installation for No Wall Studs at Corner Holes Figures 1Installation for Wall Studs at Both Corner Holes Figure Mark Rear WallPrepare Upper Cabinet Attach Mounting Plate to WallNo Wall Studs at Corner Holes Figures 1 Wall Stud at One Corner Hole FigureInstall the Microwave Oven Install Damper AssemblyFor Roof Venting Installation Only C DComplete Installation For optimal venting installation, we recommend Venting Design SpecificationsRectangular to Round Transition Recommended Standard FittingsAssistance Replacement PartsAccessories Outillage et pièces Exigences DinstallationSécurité DE L’ENSEMBLE Four À MICRO­ONDES/HOTTE Dimensions à respecter lors de linstallation Exigences demplacementDimensions du produit Spécifications électriques Instructions DinstallationDépose de la plaque de montage Réorientation du moteur du ventilateurFixer la plaque de support du clapet avec la vis Identifier la position du/des poteaux du colombage mural Configurations possibles du colombage muralTracé sur le mur arrière Un trou d’angle face à un poteau du colombage mural Figure Perçage de trous dans le mur arrièreFixation de la plaque de montage sur le mur Préparation du placard mural Installation du four à micro-ondes Installation du module du clapet anti­refluxAchever linstallation Raccord de transition rectangulaire/rond Raccords standard recommandésSPÉCIFICATIONS/CONCEPTION DU Circuit Dévacuation Longueur recommandée du circuit dévacuation AccessoiresPièces de rechange Conduit de dia 15,2 cm = longueur totale 73 pi 22,2 m