INSTALLATION REQUIREMENTS

Tools and Parts

Tools Needed

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Location Requirements

Check the opening where the microwave oven will be installed. The location must provide:

Minimum installation dimensions. See “Installation

 

Dimensions” illustration.

Minimum one 2" x 4" (50.8 x 101.6 mm) wood wall stud and

Measuring tape

Pencil

Masking tape or thumbtacks

Scissors

No. 2 Phillips screwdriver

No. 3 Phillips screwdriver for 1/4-20 x 3" bolts

Electric drill

3/16" (5 mm), 3/8" (10 mm) drill bits

3/4" (19 mm) hole saw

Stud finder

7/16" socket wrench

(or box wrench) for 1/4" x 2" lag screws

1½" (3.8 cm) diam. hole drill bit for wood or metal cabinet

Keyhole saw

Caulking gun and weatherproof caulking compound

Duct tape

minimum 3/8" (9.5 mm) thickness drywall or plaster/lath within

cabinet opening.

Support for weight of 150 lbs (68 kg), which includes

microwave oven and items placed inside the microwave oven

and upper cabinet.

Grounded electrical outlet inside upper cabinet. See

“Electrical Requirements” section.

NOTES:

If installing the microwave oven near a left sidewall, make sure

there is at least 6" (15.2 cm) of clearance between the wall and

the microwave oven, so that the door can open fully.

Some cabinet and building materials are not designed to

withstand the heat produced by the microwave oven for

cooking. Check with your builder or cabinet supplier to make

sure that the materials used will not discolor, delaminate or

Parts Supplied

For reorder information, see “Replacement Parts” section.

NOTE: The hardware items listed here are for wood studs. For other types of wall structures, be sure to use appropriate fasteners.

A B C D E F

G

sustain other damages.

Special Requirements

For Wall Venting Installation Only:

Cutout must be free of any obstructions so that the vent fits properly, and the damper blade opens freely and fully.

For Roof Venting Installation Only:

If you are using a rectangular to round transition piece, the 3" (7.6 cm) clearance needs to exist above the microwave oven so that the damper blade can open freely and fully. See “Rectangular to Round Transition” illustration in “Venting Design Specifications” section.

A. 1/4-20 x 3" bolts (4) B. Washers (2)

C. Toggle nuts (2)

D. 1/4" x 2" lag screws (2) E. Sheet metal screws (2)

F. Power supply cord bushing (1)

G. Damper assembly (for wall or roof venting)

Not Shown:

Upper cabinet template

Mounting plate (attached to back of microwave oven)

Aluminum grease filters

Charcoal filters (Depending on model, charcoal filters may not be included. See Use and Care Guide.)

NOTE: Depending on model, aluminum grease filter and charcoal filter may be combined.

Materials needed

Standard fittings for wall or roof venting. See “Venting Design Specifications” section.

2

Image 2
Contents Microwave Hood Combination Installation Instructions Microwave Hood Combination SafetyLocation Requirements Installation RequirementsTools and Parts Electrical Requirements Product DimensionsInstallation Dimensions RequiredRemove Mounting Plate Installation InstructionsWall Venting Installation Only Rotate Blower MotorRoof Venting Installation Only CD EPossible Wall Stud Configurations Locate Wall StudsInstallation for Wall Studs at Both Corner Holes Figure Installation for No Wall Studs at Corner Holes Figures 1Installation for Wall Stud at One Corner Hole Figure Mark Rear WallNo Wall Studs at Corner Holes Figures 1 Attach Mounting Plate to WallPrepare Upper Cabinet Wall Stud at One Corner Hole FigureFor Roof Venting Installation Only Install Damper AssemblyInstall the Microwave Oven C DComplete Installation Rectangular to Round Transition Venting Design SpecificationsFor optimal venting installation, we recommend Recommended Standard FittingsAssistance Replacement PartsAccessories Outillage et pièces Exigences DinstallationSécurité DE L’ENSEMBLE Four À MICRO­ONDES/HOTTE Dimensions à respecter lors de linstallation Exigences demplacementDimensions du produit Dépose de la plaque de montage Instructions DinstallationSpécifications électriques Réorientation du moteur du ventilateurFixer la plaque de support du clapet avec la vis Configurations possibles du colombage mural Identifier la position du/des poteaux du colombage muralTracé sur le mur arrière Un trou d’angle face à un poteau du colombage mural Figure Perçage de trous dans le mur arrièreFixation de la plaque de montage sur le mur Préparation du placard mural Installation du module du clapet anti­reflux Installation du four à micro-ondesAchever linstallation Raccord de transition rectangulaire/rond Raccords standard recommandésSPÉCIFICATIONS/CONCEPTION DU Circuit Dévacuation Pièces de rechange AccessoiresLongueur recommandée du circuit dévacuation Conduit de dia 15,2 cm = longueur totale 73 pi 22,2 m