KitchenAid Microwave Oven Attach Mounting Plate to Wall, Prepare Upper Cabinet

Page 8

Attach Mounting Plate to Wall

NOTE: Secure the mounting plate to the wall at both bottom corner holes drilled into the wall studs and/or drywall using either 1/4-20 x 3" round-head bolts and toggle nuts or 1/4 x 2" lag screws.

Refer to illustrations in “Possible Wall Stud Configurations” in “Locate Wall Stud(s)” section.

No Wall Studs at Corner Holes (Figures 1 & 2)

NOTE: The mounting plate must be secured to the wall on at least 1 wall stud as well as at both bottom corners.

1.With the support tabs of the mounting plate facing forward, insert 1/4-20 x 3" round-head bolts through both bottom corner holes of mounting plate.

2.Start toggle nuts on bolts from the back of the mounting plate. Leave enough space for the toggle nuts to go through the wall and to open.

B

A

C

A. 1/4-20 x 3" round-head bolt

B. Mounting plate

C. Spring toggle nut

3.Position mounting plate on the wall, making sure that the top of the mounting plate is aligned with the front edge of the upper cabinet.

4.Push the 2 bolts with toggle nuts through the drywall, and finger tighten the bolts to make sure toggle nuts have opened against drywall.

C

D

A

B

A. 1/4-20 x 3" round-head bolt

B. Mounting plate

C.Drywall

D.Spring toggle nut

5.Insert lag screw(s) into the holes drilled into wall stud(s) in Step 2 of “Installation for No Wall Studs at Corner Holes” in the “Drill Holes in Rear Wall” section.

6.Check alignment of mounting plate, making sure it is level.

7.Securely tighten all lag screws and bolts.

Wall Stud at One Corner Hole (Figure 3)

1.With the support tabs of the mounting plate facing forward, insert a 1/4-20 x 3" round-head bolt through the corner hole that fits over the 3/4" (19 mm) hole drilled in Step 3 of “Installation for One Wall Stud at One Corner Hole” in the “Drill Holes in Rear Wall” section.

2.Start a toggle nut on the bolt from the back of the mounting plate. Leave enough space for the toggle nut to go through the wall and to open.

3.Position mounting plate on the wall, making sure that the top of the mounting plate is aligned with the front edge of the upper cabinet.

4.Push the bolt with toggle nut through the drywall, and finger tighten the bolt to make sure toggle nut has opened against drywall.

5.Insert a lag screw into the remaining bottom corner hole.

6.If installing on a second wall stud, insert a lag screw into the other hole drilled in Step 2 of “Installation for One Wall Stud at One Corner Hole” in the “Drill Holes in Rear Wall” section.

7.Check alignment of mounting plate, making sure it is level.

8.Securely tighten the lag screw(s) and bolt.

Wall Studs at Both Corner Holes (Figure 4)

1.Position mounting plate on the wall, making sure that the top of the mounting plate is aligned with the front edge of the upper cabinet.

2.Insert lag screws into both bottom corner holes.

3.Check alignment of mounting plate, making sure it is level.

4.Securely tighten the lag screws.

Prepare Upper Cabinet

1.Disconnect power to outlet.

2.Remove all contents from upper cabinet.

3.Place Upper Cabinet Template against the bottom of the upper cabinet, and attach with tape or thumbtacks. Make sure the template centerline aligns with the vertical centerline on the rear wall.

The “rear wall” arrows must be against the rear wall so that the holes cut into the upper cabinet align with the holes in the top of the microwave oven.

NOTE: If the upper cabinet has a frame around it, trim the template edges so that it fits inside the frame, against the upper cabinet bottom. The template has trim lines to use as guides.

4.Make sure the 10⁷⁄₁₆" (26.5 cm) dimension from the rear wall to points “D” and “E” on the template is maintained.

Upper-cabinet template

 

D

 

E

10⁷⁄₁₆"

 

10⁷⁄₁₆"

(26.5 cm)

F

(26.5 cm)

 

G

 

 

8

Image 8
Contents Microwave Hood Combination Installation Instructions Microwave Hood Combination SafetyLocation Requirements Installation RequirementsTools and Parts Product Dimensions Installation DimensionsElectrical Requirements RequiredInstallation Instructions Wall Venting Installation OnlyRemove Mounting Plate Rotate Blower MotorRoof Venting Installation Only CD EPossible Wall Stud Configurations Locate Wall StudsInstallation for No Wall Studs at Corner Holes Figures 1 Installation for Wall Stud at One Corner Hole FigureInstallation for Wall Studs at Both Corner Holes Figure Mark Rear WallAttach Mounting Plate to Wall Prepare Upper CabinetNo Wall Studs at Corner Holes Figures 1 Wall Stud at One Corner Hole FigureInstall Damper Assembly Install the Microwave OvenFor Roof Venting Installation Only C DComplete Installation Venting Design Specifications For optimal venting installation, we recommendRectangular to Round Transition Recommended Standard FittingsAssistance Replacement PartsAccessories Outillage et pièces Exigences DinstallationSécurité DE L’ENSEMBLE Four À MICRO­ONDES/HOTTE Dimensions à respecter lors de linstallation Exigences demplacementDimensions du produit Instructions Dinstallation Spécifications électriquesDépose de la plaque de montage Réorientation du moteur du ventilateurFixer la plaque de support du clapet avec la vis Configurations possibles du colombage mural Identifier la position du/des poteaux du colombage muralTracé sur le mur arrière Un trou d’angle face à un poteau du colombage mural Figure Perçage de trous dans le mur arrièreFixation de la plaque de montage sur le mur Préparation du placard mural Installation du module du clapet anti­reflux Installation du four à micro-ondesAchever linstallation Raccord de transition rectangulaire/rond Raccords standard recommandésSPÉCIFICATIONS/CONCEPTION DU Circuit Dévacuation Accessoires Longueur recommandée du circuit dévacuationPièces de rechange Conduit de dia 15,2 cm = longueur totale 73 pi 22,2 m