ENGLISH
TROUBLESHOOTING
SYMPTOM | POSSIBLE CAUSE | SUGGESTED REMEDY |
|
|
|
Pilot will not light | Gas supply off | Check main / unit gas valves |
|
|
|
| Air in lines | Turn pilot valve on. Attempt to |
|
| light pilot every 15 sec. |
| Pilot valve not on | Turn pilot valve on / adjust |
|
|
|
Burners won’t light | Gas supply off | Check main / unit gas valves |
|
|
|
| Air in lines | Turn gas valve on. Attempt to |
|
| light pilot every 15 sec. |
| Pilot burner not lit | Turn off gas - allow unit to |
|
| vent for 5 minutes. Turn gas |
|
| back on and light pilot |
|
|
|
One burner assembly | Control not on | Turn control knob to ON |
won’t light |
| Set to desired setting when lit |
| Water in burner | Remove burner and dry |
|
| thoroughly |
| Damaged temperature control, | Contact Authorized Wells |
| burner or other internal | Service Agency for repairs |
| component |
|
Portions of a burner won’t light or | Burner wet or flame opening(s) | Clean and dry burner |
have erratic flame | clogged |
|
Burner not hot enough | Temperature control not set | Adjust for desired temperature |
|
|
|
| Shutter or nozzle out of | Contact qualified technician for |
| adjustment | adjustment |
| Damaged temperature control, | Contact Authorized Wells |
| burner or other internal | Service Agency for repairs |
| component |
|
|
|
|
|
| NOTE: There are no user |
|
| serviceable components in the |
|
| burner assemblies or in the |
|
| control valves. In all cases of |
|
| damage or malfunction, |
|
| contact your Authorized Wells |
|
| Service Agency for repairs. |
122 306626 OpManual for