Whirlpool 36, 48 Install Hood Liner Internal Blower Motor, Single Blower Motor Assembly, C B A

Page 9
Install Hood Liner Internal Blower Motor

Install Hood Liner Internal Blower Motor

1.Install the hood liner blower motor assembly inside the hood liner canopy with the wiring connection to the left for the single motor system and to the front or top for the dual motor system.

Single Blower Motor Assembly

A

A. Wiring connection

3.Run the power supply wires and connector from the range hood through the hole in the right end of the motor mounting plate.

A

B

A. Motor mounting plate hole

B. Power supply wires and connector

4.Push the right end of the motor mounting plate up and snap it into the spring tab.

NOTE: The spring tab should be outside the slot in the mounting plate.

Dual Blower Motor Assembly

A

Single Blower Motor AssemblyA

Dual Blower Motor Assembly B

A. Wiring connection

2.Slide the left mounting plate flange under the motor mounting bracket.

AB

A. Motor mounting bracket B. Mounting plate left flange

A. Motor mounting plate

B. Spring clip

5.Align mounting holes in motor mounting plate with motor mounting clip nuts and install 6 x 16 mm screws and

6.4 mm lock washers (quantity 2 for single motor; quantity 5 for dual motor).

C C Manual background

B

A

A. Screw with lock washer

B. Mounting hole in motor mounting plate

C. Clip nut (6 mm)

9

Image 9
Contents FOR RESIDENTIAL USE ONLY IMPORTANT READ AND SAVE THESE INSTRUCTIONSIMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RÉSIDENTIELLE UNIQUEMENTTABLE DES MATIÈRES RANGE HOOD SAFETYDANGER TABLE OF CONTENTSREAD AND SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONSFor Mobile Home Installations INSTALLATION REQUIREMENTSCabinet Dimensions Tools and PartsCold weather installations Product DimensionsVenting Requirements Makeup airCalculating Vent System Length Electrical RequirementsExample vent system C D B APrepare Location INSTALLATION INSTRUCTIONSHood Liner Support Preparation Complete PreparationInstall Range Hood Liner Install Hood Liner Internal Blower MotorPrepare the Internal Blower System B A D E CSingle Blower Motor Assembly Install Hood Liner Internal Blower MotorDual Blower Motor Assembly C B AInstall In-lineBlower System Install Hood Liner In-LineExternal TypeBlower Motor Prepare for Mounting the In-LineBlower SystemBlower Motor System Make Electrical Connections for In-LineElectrical Connection Inside In-lineBlower System Complete Preparationto Hood Liner Make Electrical Power Supply ConnectionDisconnect power before servicing Electrical Shock HazardOperation Complete Installation and CheckA B CA A E D ARANGE HOOD USE Adjusting the fanRange Hood Controls Operating the fanRANGE HOOD CARE CleaningExterior Surfaces Metal Grease FilterMotor Characteristics WIRING DIAGRAMSE112A Motor Resistance OhmsAccessories ASSISTANCE OR SERVICEIf you need replacement parts In the U.S.ALIMITED WARRANTY WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTYITEMS EXCLUDED FROM WARRANTY This limited warranty does not coverDANGER AVERTISSEMENT SÉCURITÉ DE LA HOTTE DE CUISINIÈRELIRE ET CONSERVER CES INSTRUCTIONS IMPORTANTES INSTRUCTIONS DE SÉCURITÉExigences demplacement EXIGENCES DINSTALLATIONInstallation dans une résidence mobile Dimensions du placardInstallations pour régions à climat froid Dimensions du produitExigences concernant l’évacuation Air d’appointExemple de circuit d’évacuation Spécifications électriquesCalcul de la longueur du circuit d’évacuation Décharge à travers le toitPréparation de lemplacement INSTRUCTIONS D’INSTALLATIONAVERTISSEMENT Préparation du support de la caisse de la hotteInstallation de la caisse de la hotte Installation dumoteurdu ventilateur internede la caisse de la hotte Préparation du système de ventilation interneEnsemble à un seul moteur-ventilateur Ensemble à deux moteurs-ventilateursC B A Préparation du système de ventilation en ligne Installation du système de ventilation en ligneAVERTISSEMENT A B C DAVERTISSEMENT Achever la préparationC D E F G H Risque de choc électrique AVERTISSEMENTRelier le ventilateur à la terre C D E F G HRéalisation des connexions de Achever linstallation et vérifier lel’alimentation électrique à la caisse de la hotte fonctionnementCommande de la lampe Commandes de la hotte de cuisinièreUTILISATION DE LA HOTTE Fonctionnement du ventilateurENTRETIEN DE LA HOTTE Remplacement d’une lampe à halogèneNettoyage Surfaces externesRésistance du moteur ohms SCHÉMA DE CÂBLAGECaractéristiques du moteur SE112AAccessoires ASSISTANCE OU SERVICEAu Canada Si vous avez besoin de pièces de rechangeWHIRLPOOL CORPORATION GARANTIE DES GROS APPAREILS MÉNAGERSGARANTIE LIMITÉE ARTICLES EXCLUS DE LA GARANTIE2011 Whirlpool Corporation W10331011B2/11 All rights reserved