Hobart HPGF15 manual Filling the Kettle with Liquid Shortening, Turning the Fryer on

Page 11

FILLING THE KETTLE WITH LIQUID SHORTENING

Oil Capacity: 40 lb/5 gal (18 kg/19 L).

Use only a pure vegetable hydrogenated oil prescribed for use in pressure fryers, such as Mel Fry, Crystal, FryMax or Gold Label. Never add suet.

Close drain valve (Fig. 7). Fill kettle with liquid shortening.

If you use a solid shortening, melt before filling kettle.

If shortening is hot, fill kettle to the oil level line on the side of the kettle (Fig. 8).

If shortening is room temperature, fill kettle to 3/4" below the oil level line. This level allows for oil expansion when heated. Do not overfill.

Regularly add enough oil to keep the oil level in the kettle at the oil level line.

When changing to new oil, fill to 3/4" below the oil level line.

DO NOT operate the fryer with no oil in the kettle.

OIL LEVEL LINE

DRAIN

VALVE

HANDLE

 

PL-40937-2

 

 

 

 

 

 

 

 

 

PL-41597-1

Fig. 7

 

Fig. 8

TURNING THE FRYER ON

CAUTION: Before turning the burner on, the kettle must be filled to the correct level with liquid shortening. If this is not done, the kettle walls can be damaged. Warpage can cause leaks.

To turn the fryer ON, place the power switch in the ON position and set the thermostat at 325°F (163°C). The burner will ignite and the white cooking light will glow, indicating that the burner is calling for heat. The white cooking light will glow when the oil is below the selected temperature. When oil reaches set temperature, the white cooking light goes out.

Before the first load of the day, it is recommended that you allow the fryer to cycle one time before loading food. When the white cooking light glows, wait until it goes out. When the white cooking light glows for the second time, allow it to go out a second time, then cooking may begin. Allow at least 45 minutes for this operation.

– 11 –

Image 11
Contents Truct For Your Safety Important for Your SafetyTable of Contents Unpacking InstallationLocation Installation Codes and StandardsAssembly Installing Casters GAS Connections Exhaust PipeLighting Instructions Testing the GAS Supply SystemFlue Connections Electrical ConnectionsPL-40937-1 PL-40936-1 Before First USE OperationTurning the Fryer on Filling the Kettle with Liquid ShorteningFrying Procedure for ALL Foods Extended Shutdown HIGH-LIMIT SwitchPower Failure Turning the Fryer OFFFood PRESSURE-RELIEF ValveSuggested Cooking Guide TempMin Using the HMF50 or HMF85 FilterOther Items Which May Be Prepared in the Pressure Fryer Temp Time FoodFiltering Oil at the End of the Production Day Aluminum Kettle CleaningDaily Cleaning Stainless Steel Weekly Cleaning More Often if Required Solenoid Assembly Fig Cleaning After Every Production Period Exhaust TankKettle Tilt Lid Pressure-Relief Valve Monthly Cleaning Exhaust TankRemove Bolt Kettle Pressure-Regulator Assembly MaintenanceLID O-RING Seal Replacement Other O-RING Seal ReplacementsVent Cleaning Port Plug ScrewLid will not lock do not Operate Fryer TroubleshootingSymptom Possible Causes