Hobart FT900SBD, FT900SDBD, FT900DBD Entering the Parameters Menu, Navigating the Parameters Menu

Page 17

Entering the Parameters Menu

NOTE: The parameters can be changed anytime the display is active, which is when the machine is operating or in idle mode.

To enter the Parameters menu to edit options:

1)Press the MENU key from the main screen.

a. You will be prompted on-screen asking if you wish to exit the menu.

2)Press the UP or DOWN key repeatedly until you reach the ENTER SECURITY CODE? screen.

3)Press the ENTER key to indicate that you want to enter the code.

a.You will now be prompted with SECURITY CODE: on the top line and a single digit and three asterisks [ 0*** ] on the bottom line.

4)Use the UP and DOWN keys to change the digit of the Security Code to the appropriate value*.

*The default Security Code to enter Manager Mode is 1001. This code can be changed by anyone with this knowledge and it is recommended to change it from the default. If the code is ever lost for some reason, it can be reset by Hobart Service.

NOTE: Resetting the code is not covered under your warranty, whether you are in the initial warranty period or in the extended warranty period.

5)Press the ENTER key to move to the next digit to the right.

6)Repeat steps 4 and 5 for each digit.

a.After pressing ENTER on the fourth digit, you will immediately return to the ENTER SECURITY CODE? screen.

7)You will know you entered the code correctly if the letter in the lower left corner reads M. Refer to Machine Operation and Programming Security Levels on page 15 for more details on other letters that may appear.

a.If it does not match, repeat steps 3 through 7.

b.If it does match, continue to step 8.

8)Press the UP or DOWN keys repeatedly until you reach the EDIT PARAMETERS? screen.

a.If you do not see this screen after scrolling all of the way through, the Security Code was not entered properly. Repeat the steps starting from 2.

9)Press the ENTER key.

a.You are now in the Parameters edit menu; the display shows the first editable parameter.

Navigating the Parameters Menu

NOTE: The security level must be elevated to the Super Operator or higher to enter the Parameters Menu. Refer to Machine Operation and Programming Security Levels on page 15 for more details.

Hobart believes that the default settings that leave the factory are suitable for the majority of kitchen operations. However, there are cases where kitchen managers may find the need to change one or more options (Parameters Menu — Table 1); the Parameters Menu allows these changes.

Within the Parameters Menu, the manager (or operator, in some cases) may modify factory default settings. The menu structure and description of each option are detailed below. Please contact Hobart Service if you are uncomfortable changing any setting or are unsure of which one(s) to change.

– 17 –

Image 17
Contents FT900 Series Dishwashers Table of Contents Machine Preparation Check before beginning operation FT900 Series Dishwashers OperationTank Filling Dishwashing Alternative Temperature Display Names Table aEmpty Strainer Baskets During Operation AS Necessary Recommended Minimum TemperaturesLoading UnloadingCleaning Clean Sensor Openings AT Load END of Machine Cleaning the TOP Duct DOs and DONTs for Your NEW Hobart Dishwasher Cleaning the BLOWER-DRYER AIR FilterLoad Curtains and Drainback PANS, Model FT900To L Operation Center Section Curtains and Drainback PANS, Model FT900DTo L Operation 4 Center Section Curtains and Drainback PANS, Model FT900SFT900SD To L Operation 4 Center Section Curtains and Drainback PANS, Model FT900SDOperator O Machine Operation and Programming Security LevelsSuperOperator SO Manager MMenu Display Prompts User Programming InstructionsNavigating the Parameters Menu Entering the Parameters MenuParameters Menu Table Parameters MenuCommunications Setup Menu Table Communications Setup MenuLubrication Line StrainersMotors Conveyor GearmotorConveyor Drive Chain Conveyor Speed AdjustmentConveyor Shaft Flange Bearings Conveyor Take-Up UnitDisconnect electrical power supplyies and follow Symptom Possible CauseElectronic Sensor AT Load END Hobart Service Display Reads Possible Resolution Page Page Date