SYMPTOM | POSSIBLE CAUSE | |
| NOTE: If symptom(s) persist after possible causes have been checked, contact | |
| Hobart Service. | |
|
| |
Tanks Not Heating. | 1. Low water safety devices shut off heat. Check for proper water level. | |
| 2. | Lower float(s) do not move freely. |
| 3. | Circuit breaker(s) to heat system tripped (electric heat). |
| 4. | Steam supply valve(s) are not opened completely or supply pressure too low |
|
| (steam heat). |
| 5. | Overtemp protector tripped (electric heat). Contact Hobart Service. |
| 6. | Failed heating element (electric heat). Contact Hobart Service. |
| 7. | Bucket trap not functioning correctly (steam heat). Contact Hobart Service. |
| 8. | Improperly operating steam solenoid valve(s) (steam heat). Contact Hobart |
|
| Service. |
|
| |
No Fill or Slow Fill. | 1. Door(s) are open. | |
| 2. | Main fill (water supply valve) could be closed. |
| 3. | Upper and / or lower fill floats do not move freely. |
| 4. | Dirty line strainer (Fig. 42) causing reduced water flow. Turn off water supply, |
|
| remove strainer cap, withdraw and clean screens. |
| 5. | Problem with solenoid valve. Contact Hobart Service. |
| 6. | Low incoming water supply pressure. |
| 7. | Drain(s) open. |
|
| |
No | 1. Blower or motor not operating properly. | |
(Electric Heat Blower- | 2. Circuit breaker to electric | |
Dryer). | 3. Overtemp protector tripped; red overtemp indicator light is lit. Contact Hobart | |
|
| Service. |
No | 1. Blower or motor not operating properly. | |
(Steam | 2. Improperly operating steam solenoid valve (when equipped). | |
| 3. | Steam supply valve is not completely open or supply pressure is too low. |
| 5. | Bucket trap not functioning correctly. |
| 6. | Missing or dirty filter. |
|
|
|