Conveyor Drive Chain

Inspect the drive chain (Fig. 36) regularly and lubricate as required with Hykogeen Concentrate A (supplied).

Conveyor Shaft Flange Bearings

Located at both load and unload ends of the machine and at the front and back, these bearings should be lubricated every four months. Grease fittings at each of the four bearings, a grease gun and 16 ounces of Chevron SRI #2 grease are provided for this purpose. Fig. 37 shows one of the take-up units at the load end; Fig. 38 shows one of the conveyor bearings at the unload end.

CONVEYOR TAKE-UP UNIT

GREASE FITTING

GREASE

FITTING

LUBRICATE GUIDES

Fig. 37

Fig. 38

Conveyor Take-Up Unit

Lubricate the two conveyor take-up unit guides at the load ends of the machine at least twice a year using the Chevron FM Grease ALC EP 2, provided for this purpose.

CONVEYOR SPEED ADJUSTMENT

The conveyor speed comes preset from the factory. Conveyor speed can be adjusted to run faster or slower by the customer. Refer to User Programming, pages 15 – 19.

– 21 –

Image 21
Contents FT900 Series Dishwashers Table of Contents Machine Preparation Check before beginning operation FT900 Series Dishwashers OperationTank Filling Dishwashing Alternative Temperature Display Names Table aEmpty Strainer Baskets During Operation AS Necessary Recommended Minimum TemperaturesLoading UnloadingCleaning Clean Sensor Openings AT Load END of Machine Cleaning the TOP Duct DOs and DONTs for Your NEW Hobart Dishwasher Cleaning the BLOWER-DRYER AIR FilterLoad Curtains and Drainback PANS, Model FT900To L Operation Center Section Curtains and Drainback PANS, Model FT900DTo L Operation 4 Center Section Curtains and Drainback PANS, Model FT900SFT900SD To L Operation 4 Center Section Curtains and Drainback PANS, Model FT900SDOperator O Machine Operation and Programming Security LevelsSuperOperator SO Manager MMenu Display Prompts User Programming InstructionsNavigating the Parameters Menu Entering the Parameters MenuParameters Menu Table Parameters MenuCommunications Setup Menu Table Communications Setup MenuLubrication Line StrainersMotors Conveyor GearmotorConveyor Drive Chain Conveyor Speed AdjustmentConveyor Shaft Flange Bearings Conveyor Take-Up UnitDisconnect electrical power supplyies and follow Symptom Possible CauseElectronic Sensor AT Load END Hobart Service Display Reads Possible Resolution Page Page Date