SYMPTOM | POSSIBLE CAUSE | |
| NOTE: If symptom(s) persist after possible causes have been checked, contact | |
| Hobart Service. | |
|
| |
Display Reads | Possible Resolution | |
|
| |
Door(s) Open | Close all inspection doors. | |
|
| |
Unload Dishes | Remove all ware from unload section of the machine, starting with the ware closest | |
| to the machine chambers. Finally remove the last ware that is in contact with the dish | |
| limit bar. | |
|
| |
Temp Err - [Tank Name] | Ensure lower float assembly in indicated tank is not visibly damaged and sufficient | |
| water is in the tank to cover the lower float. | |
|
|
|
Fnl Rinse Temp Low | 1. | If problem is intermittent and only occurs after the machine has been idle for |
|
| several minutes, this is normal. The problem will correct itself after running |
|
| several pieces of ware through the machine. |
| 2. | Check that the final rinse booster tank circuit breaker is on and not tripped (if |
|
| equipped.) |
| 3. | Check that the final rinse booster tank overtemp circuit is not tripped (if equipped). |
| 4. | Ensure that the building supply water to the final rinse booster tank is at least the |
|
| minimum specified by the booster manufacturer. |
|
| |
Temp Err - Fnl Rns | Ensure that the supply water valve to the final rinse booster is open. | |
|
|
|
Check Water Level | 1. | Ensure all drains are closed and free of debris. |
| 2. | Check that water supply valve is open |
| 3. | Open inspection doors and check water level of all tanks. Watershould be |
|
| about 1 inch down from top of strainer pan or higher . Do not forget to check |
|
| the water level of the dual rinse tank (models FT900D or FT900SD) which is |
|
| located behind the control box directly beneath the final rinse arms. Close |
|
| inspection doors. |
| 4. | If tanks fail to fill after another 20 minutes, contact Hobart Service. |
|
| |
Reset Required | Place machine in Standby by pressing the Power key. Wait at least 60 seconds | |
| before powering on the machine. | |
|
|
|
– 25 –