Frymaster YFPRE1817E operation manual Filter Operation

Page 22

YFPRE18E ELECTRIC FRYER

CHAPTER 4: BUILT-IN FILTRATION

4.4.2 Filter Operation (cont.)

The blue handle drains the frypot. The red handle operates the filter pump.

5.After ensuring the filter pan is correctly positioned under the drain tube and the pan is properly connected, open the drain valve by pulling the blue handle to the left. Drain only one frypot at a time.

6.After all oil has drained from the frypot into the filter pan, twist the red handle to open the oil return line and activate the filter pump.

7.Oil will begin to pump from the filter pan into the frypot. If the frypot has sediment deposits, clean with the cleaning brush included with the fryer.

8.Allow the oil to circulate for approximately 30 minutes (process known as "polishing") to remove suspended particles.

9.After the filter cycle is complete, close the drain valve (push the blue handle to the left until it stops) and allow the fryer to refill.

10.After all oil is pumped back into the frypot, bubbles will form, indicating air in the oil return lines. Allow the oil to bubble for 10-15 seconds to ensure all oil is evacuated from the return lines. Twist the red handle to close the oil return valve and deactivate the filter pump.

11.If the oil level is low, add oil until the level is at the top OIL LEVEL line. Remember, the oil is at operating temperature.

12.Replace the frypot grid, using care not to splash hot oil. Turn the fryer on.

4-7

Image 22
Contents Hour Service Hotline YFPRE1817ECanada Page Table of Contents General Safety InformationYFPRE18E Electric Fryers Introduction Computer InformationInstallation, Operating, and Service Personnel DefinitionsShipping Damage Claim Procedure Service InformationYFPRE18E Electric Fryer Installation Instructions Electrical Grounding Requirements Do not block the area around the base or under the fryersAustralian Requirements Power Requirements Three 3 Phase RequirementsPage YFPRE18E Electric Fryer Operating Instructions Finding Your WAY around the YFPRE18E Electric FryerSetup Equipment Setup and Shutdown ProceduresShutdown Controllers Page YFPRE18E Electric Fryer BUILT-IN Filtration Filtration Preparation GeneralAssembling the Filter Crumb screen to rest on the top edges Installing the Filter Daily Filtration OperationOperating the Filter Filtering ToolsPrior to filtering, skim any large debris from oil in frypot Filter Operation YFPRE18E Electric Fryer BUILT-IN Filtration YFPRE18E Electric Fryer Preventative Maintenance Fryer Page YFPRE18E Electric Fryer Operator Troubleshooting IntroductionController wont Problem Probable Causes Corrective ActionTroubleshooting Controller and Heating Problems ActivateFilter pump wont Problem Probable CausesFiltration Problems StartReturn to frypot Filter pump runsBut oil does not There is no bubblingThis page Intentionally Left Blank Service Hotline