Frymaster YFPRE1817E operation manual

Page 26

5.2.2 Built-In Filtration System

DANGER

The crumb tray in fryers equipped with a filter system must be emptied into a fireproof container at the end of frying operations each day. Some food particles can spontaneously combust if left soaking in certain shortening material.

Inspect all oil-return and drain lines for leaks and verify that all connections are tight.

Inspect the filter pan for leaks and cleanliness. If there is a large accumulation of crumbs in the crumb basket, advise the owner/operator that the crumb basket should be emptied into a fireproof container and cleaned daily.

Verify that all O-rings and seals (including those on the quick-disconnect fittings) are present and in good condition. Replace O-rings and seals if worn or damaged.

Check filtration system integrity as follows:

Verify that filter pan cover is present and properly installed.

With the filter pan empty, place each oil return handle, one at a time, in the ON position. Verify that the pump activates and that bubbles appear in the oil of the associated frypot.

Close all oil return valves (i.e., place all oil return handles in the OFF position). Verify proper functioning of each oil return valve by activating the filter pump using the lever on one of the oil return handle microswitches. No air bubbles should be visible in any frypot.

Verify that the filter pan is properly prepared for filtering, and then drain a frypot of oil heated to 350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in the ON position. Allow all oil to return to the frypot, indicated by bubbles in the oil. Return the oil return handle to the OFF position. The frypot should have refilled in no more than 2 minutes and 30 seconds.

5-3

Image 26
Contents Hour Service Hotline YFPRE1817ECanada Page Table of Contents General Safety InformationYFPRE18E Electric Fryers Introduction Computer InformationInstallation, Operating, and Service Personnel DefinitionsShipping Damage Claim Procedure Service InformationYFPRE18E Electric Fryer Installation Instructions Australian Requirements Do not block the area around the base or under the fryersElectrical Grounding Requirements Power Requirements Three 3 Phase RequirementsPage YFPRE18E Electric Fryer Operating Instructions Finding Your WAY around the YFPRE18E Electric FryerShutdown Equipment Setup and Shutdown ProceduresSetup Controllers Page YFPRE18E Electric Fryer BUILT-IN Filtration Assembling the Filter GeneralFiltration Preparation Crumb screen to rest on the top edges Installing the Filter Daily Filtration OperationOperating the Filter Filtering ToolsPrior to filtering, skim any large debris from oil in frypot Filter Operation YFPRE18E Electric Fryer BUILT-IN Filtration YFPRE18E Electric Fryer Preventative Maintenance Fryer Page YFPRE18E Electric Fryer Operator Troubleshooting IntroductionController wont Problem Probable Causes Corrective ActionTroubleshooting Controller and Heating Problems ActivateFilter pump wont Problem Probable CausesFiltration Problems StartReturn to frypot Filter pump runsBut oil does not There is no bubblingThis page Intentionally Left Blank Service Hotline