Frymaster YFPRE1817E operation manual YFPRE18E Electric Fryer Installation Instructions, General

Page 8

YFPRE18E ELECTRIC FRYER

CHAPTER 2: INSTALLATION INSTRUCTIONS

2.1General

Proper installation is essential for the safe, efficient, trouble-free operation of this appliance.

Qualified, licensed, and/or authorized installation or service personnel, as defined in Section 1.6 of this manual, should perform all installation and service on Frymaster equipment.

Failure to use qualified, licensed, and/or authorized installation or service personnel (as defined in Section 1.6 of this manual) to install or otherwise service this equipment will void the Frymaster warranty and may result in damage to the equipment or injury to personnel.

Where conflicts exist between instructions and information in this manual and local or national codes or regulations, installation and operation shall comply with the codes or regulations in force in the country in which the equipment is installed.

Service may be obtained by contacting your local Factory Authorized Service Center.

NOTICE

All fryers shipped without factory supplied cords and plug assemblies must be hardwired using flexible conduit to the terminal block located on the rear of the fryer. These fryers should be wired to NEC specifications. Hardwired units must include installation of restraint devices.

DANGER

Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. A restraint kit is provided with the fryer. If the restraint kit is missing contact your local Frymaster Factory Authorized Service Center (FASC) for part number 826-0900.

NOTICE

If this equipment is wired directly into the electrical power supply, a means for disconnection from the supply having a contact separation of at least 3-mm in all poles must be incorporated in the fixed wiring.

NOTICE

This equipment must be positioned so that the plug is accessible unless other means for disconnection from the power supply (e.g., a circuit breaker) is provided.

NOTICE

If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of not less than 167°F (75°C).

NOTICE

If the electrical power supply cord is damaged, it must be replaced by a Frymaster Dean Factory Authorized Service Center technician or a similarly qualified person in order to avoid a hazard.

2-1

Image 8
Contents Hour Service Hotline YFPRE1817ECanada Page Table of Contents Safety Information YFPRE18E Electric Fryers IntroductionGeneral Computer InformationInstallation, Operating, and Service Personnel DefinitionsShipping Damage Claim Procedure Service InformationYFPRE18E Electric Fryer Installation Instructions Australian Requirements Do not block the area around the base or under the fryersElectrical Grounding Requirements Power Requirements Three 3 Phase RequirementsPage YFPRE18E Electric Fryer Operating Instructions Finding Your WAY around the YFPRE18E Electric FryerShutdown Equipment Setup and Shutdown ProceduresSetup Controllers Page YFPRE18E Electric Fryer BUILT-IN Filtration Assembling the Filter GeneralFiltration Preparation Crumb screen to rest on the top edges Installing the Filter Daily Filtration OperationOperating the Filter Filtering ToolsPrior to filtering, skim any large debris from oil in frypot Filter Operation YFPRE18E Electric Fryer BUILT-IN Filtration YFPRE18E Electric Fryer Preventative Maintenance Fryer Page YFPRE18E Electric Fryer Operator Troubleshooting IntroductionProblem Probable Causes Corrective Action Troubleshooting Controller and Heating ProblemsController wont ActivateProblem Probable Causes Filtration ProblemsFilter pump wont StartFilter pump runs But oil does notReturn to frypot There is no bubblingThis page Intentionally Left Blank Service Hotline