6.2Troubleshooting
6.2.1 Controller and Heating Problems
Problem | Probable Causes | Corrective Action | |
| A. Power cord is not plugged in or | A. Plug power cord in and verify | |
| that circuit breaker is not | ||
| circuit breaker is tripped. | tripped. | |
|
|
| |
Controller won't |
| B. If any of the components in the | |
| power supply system (including | ||
activate. | B. Controller or power supply | ||
the transformer and interface | |||
| |||
| component or interface board has | board) fail, power will not be | |
| failed. | supplied to the controller and it | |
|
| will not function. Call FASC. | |
|
|
| |
|
| A. A drain safety switch prevents | |
|
| the heating element from being | |
| A. Drain valve is open. | energized if the drain valve is | |
| not fully closed. Verify that the | ||
|
| ||
|
| drain valve is fully closed. | |
Fryer does not heat. |
|
| |
| B. If the circuitry in the fryer | ||
|
| control system cannot determine | |
| B. One or more other components | the frypot temperature, the | |
| system will not allow the | ||
| have failed. | ||
| element to be energized or will | ||
|
| ||
|
| ||
|
| FASC. |