CHAPTER 6: OPERATOR TROUBLESHOOTING

6.1 Introduction

This section provides an easy reference guide to some of the common problems that may occur during the operation of this equipment. The troubleshooting guides that follow are intended to help correct, or at least accurately diagnose, problems with this equipment. Although the chapter covers the most common problems reported, you may encounter problems that are not covered. In such instances, the Frymaster Technical Services staff will make every effort to help you identify and resolve the problem.

When troubleshooting a problem, always use a process of elimination starting with the simplest solution and working through to the most complex. Never overlook the obvious – anyone can forget to plug in a cord or fail to close a valve completely. Most importantly, always try to establish a clear idea of why a problem has occurred. Part of any corrective action involves taking steps to ensure that it doesn’t happen again. If a controller malfunctions because of a poor connection, check all other connections, too. If a fuse continues to blow, find out why. Always keep in mind that failure of a small component may often be indicative of potential failure or incorrect functioning of a more important component or system.

Before calling a service agent or the Frymaster HOTLINE (1-800-551-8633):

Verify that electrical cords are plugged in and that circuit breakers are on.

Verify that frypot drain valves are fully closed.

DANGER

Hot oil will cause severe burns. Never attempt to move this appliance when filled with hot oil or to transfer hot oil from one container to another.

DANGER

This equipment should be unplugged when servicing, except when electrical circuit tests are required. Use extreme care when performing such tests.

This appliance may have more than one electrical power supply connection point. Disconnect all power cords before servicing.

Inspection, testing, and repair of electrical components should be performed by an authorized service agent only.

6-1

Image 27
Contents YFPRE1817E Hour Service HotlineCanada Page Table of Contents Computer Information Safety InformationYFPRE18E Electric Fryers Introduction GeneralDefinitions Installation, Operating, and Service PersonnelService Information Shipping Damage Claim ProcedureYFPRE18E Electric Fryer Installation Instructions Do not block the area around the base or under the fryers Electrical Grounding RequirementsAustralian Requirements Three 3 Phase Requirements Power RequirementsPage Finding Your WAY around the YFPRE18E Electric Fryer YFPRE18E Electric Fryer Operating InstructionsEquipment Setup and Shutdown Procedures SetupShutdown Controllers Page YFPRE18E Electric Fryer BUILT-IN Filtration General Filtration PreparationAssembling the Filter Crumb screen to rest on the top edges Daily Filtration Operation Installing the FilterFiltering Tools Operating the FilterPrior to filtering, skim any large debris from oil in frypot Filter Operation YFPRE18E Electric Fryer BUILT-IN Filtration YFPRE18E Electric Fryer Preventative Maintenance Fryer Page Introduction YFPRE18E Electric Fryer Operator TroubleshootingActivate Problem Probable Causes Corrective ActionTroubleshooting Controller and Heating Problems Controller wontStart Problem Probable CausesFiltration Problems Filter pump wontThere is no bubbling Filter pump runsBut oil does not Return to frypotThis page Intentionally Left Blank Service Hotline