6.2Troubleshooting
6.2.1 Controller and Heating Problems
Problem |
| Probable Causes | Corrective Action |
| ||
|
|
|
| A. Press the ON/OFF switch to turn the |
| |
| A. Controller not turned on. | controller on. |
|
| ||
No Display on | B. Verify controller power | cord is |
| |||
B. No power to the fryer. |
| |||||
controller. | plugged in and that circuit breaker is |
| ||||
C. Failed controller or other component. |
| |||||
| not tripped. |
|
| |||
|
|
|
|
|
| |
|
|
|
| C. Call your FAS for assistance. |
| |
|
|
|
|
|
| |
Controller displays |
|
|
| A. Press S (YES) if the vat is full, |
| |
|
|
| otherwise press T (NO). |
|
| |
IS VAT FULL? | A. | Normal operation after a filtration. |
|
| ||
B. Follow controller prompts to clear |
| |||||
YES NO after a | B. | Oil may be in the filter pan. |
| |||
message. If problem persists, call |
| |||||
filtration. |
|
|
|
| ||
|
|
| your FAS for assistance. |
|
| |
|
|
|
|
|
| |
Controller displays | Daily filter paper change prompt has | Press S (YES), follow prompts and |
| |||
CHANGE FILTER |
| |||||
PAPER? | occurred. | change the filter paper. |
|
| ||
Fryer repeatedly cycles |
|
|
| This is normal operation. | This will |
|
on and off when first | Fryer is in melt cycle. | continue until the fryer temperature |
| |||
started. |
|
|
| reaches 180ºF (82ºC). |
|
|
|
|
|
| A. Verify that all power cords are fully |
| |
| A. Main power cord not plugged in. | seated in the receptacles, locked into |
| |||
Fryer does not heat. | B. Drain is open. | place and that a circuit breaker is not |
| |||
C. Controller has failed. | tripped |
|
| |||
|
|
| ||||
| D. One or more other components have | B. Close drain. |
|
| ||
|
| failed. | C. Call your FAS for assistance |
| ||
|
|
|
| D. Call your FAS for assistance. |
| |
Fryer heats until high- |
|
|
| Turn fryer off and call your FAS for |
| |
limit trips with heat | Temperature probe or controller has failed. |
| ||||
indicator ON. |
|
|
| assistance. |
|
|
|
|
|
|
|
| |
Fryer heats until high- |
|
|
|
|
|
|
limit trips without heat | Contactor or controller has failed | Call your FAS for assistance. |
|
| ||
indicator ON. |
|
|
|
|
|
|
6.2.2 Error Messages and Display Problems |
|
|
| |||
|
|
|
|
|
| |
Problem |
| Probable Causes |
| Corrective Action |
| |
|
|
|
| Fryers using the 3000 controller can |
| |
|
|
|
| toggle between F° to C° by pressing the 9 |
| |
|
|
|
| button until Product setup is displayed. |
| |
Controller display is in |
|
|
| Press X to scroll to Tech Mode and press |
| |
wrong temperature | Incorrect display option programmed. |
| 9. Enter 1658. Press the scan button. |
| ||
scale (Fahrenheit or |
| The controller displays OFF. | Turn the |
| ||
|
|
|
| |||
Celsius). |
|
|
| controller on to check temperature. If the |
| |
|
|
|
| desired scale is not displayed, repeat. |
| |
|
|
|
| Fryers using the CM3.5 should refer to the |
| |
|
|
|
| separate Fryer Controllers User’s Manual. |
| |
Controller displays | Failed controller, failed interface board, |
| Turn the fryer off and on again. If issue |
| ||
HEATING |
| persists call your FAS for assistance. |
| |||
FAILURE. | open |
|
|
|
|