2.Press the left arrow (W) button until TECH MODE is displayed.
3.Press the check (9) button.
4.Enter 3000.
5.Press the left arrow (W) button until HI LIMIT TEST is displayed.
6.Press the check (9) button.
The controller displays HIGH LIMIT YES/NO.
7.Press the up arrow (S) button.
8.The controller displays PRESS AND HOLD CHECK.
9.Press and hold the (9) button to initiate the
The vat begins to heat. The computer displays the actual vat temperature during the test.
The fryer continues heating until the high limit trips. Generally this happens once the temperature reaches 423°F to 447°F (217°C to 231°C) for
Once the
10. Release the (9) button.
If the
The vat stops heating and the computer displays the current temperature setting alternating with the actual temperature (ex. 430F) until the temperature cools below 400°F (204°C).
11.Press the soft power button to cancel the alarm and go to OFF.
12.Follow the procedure to dispose of the oil.