Frymaster FDP65 operation manual Boil-Out Procedure

Page 25

FRYMASTER FPD65 SERIES GAS FRYERS

CHAPTER 4: FRYER OPERATIONS

4.2 Boil-Out Procedure

DANGER

Never leave the fryer unattended during the boil-out process. If the boil-out solution boils over, turn the fryer off immediately and let the solution cool for a few minutes before resuming the process. To lessen the chance of boil over, turn the fryer’s gas valve knob to the PILOT position occasionally.

WARNING

Do not drain boil-out solution into a shortening disposal unit, a built-in filtration unit, or a portable filter unit. These units are not intended for this purpose, and will be damaged by the solution.

DANGER

Remove all drops of water from the frypot before filling with cooking oil or shortening. Failure to do so will cause spattering of hot liquid when the oil or shortening is heated to cooking temperature and may cause injury to nearby personnel.

A.Pour cleaning solution into the frypot and add water to the bottom OIL LEVEL line scribed in the back of the frypot.

B.Operating thermostat-equipped fryers: Set dial/temperature controller to 225°F (107ºC), just above that of boiling water.

C.Filtration/Boil-Mode equipped fryers: Turn fryer power switch to "ON". Press the fryer- reset switch (if applicable). Turn the boil-out switch "ON".

CAUTION

If the pilot and main burner go out, the fryer(s) MUST be left completely shut down at

least 5 minutes before lighting.

D.The main burner will ignite.

E.When the solution nears boiling point, reset the temperature controller to 200°(93ºC).

F.The burners should shut off just as the water starts to boil.

CAUTION

Do not leave fryer unattended. The boil-out solution may foam and overflow if fryer is left unattended. Press ON/OFF switch to the "OFF" position (Filtration/Boil-Mode equipped fryers) or reduce temperature (Operating Thermostat equipped fryers) to control this condition.

4-3

Image 25
Contents FPD65 Series with Built-In Filtration Hour Service HotlineCanada Page Table of Contents Filtration Operation Frymaster FPD65 Series GAS Fryers Introduction Service InformationAfter Purchase Ordering PartsSafety Information Definitions Service PersonnelReceiving and Unpacking Equipment Frymaster FPD65 Series GAS Fryers Important InformationProduct Description GeneralPrinciples of Operation Pre-InstallationRating Plate Installation Standards Air Supply and Ventilation Equipment Installed at High AltitudesInstalling the Fryer Frymaster FPD65 Series GAS Fryers InstallationFrymaster FPD65 Series GAS Fryers Installation Never Allow Water or Boilout Solution Into Filter System National Code Requirements Gas ConnectionsRecommended Gas Supply Line Sizes Gas Connections Adjustments/Adaptation To Different Gases Adjustments to Different Gas Types Specifications Electrical Connections Gas Conversion ProceduresInitial Start-up Frymaster FPD65 Series GAS Fryers Fryer OperationsFrymaster FPD65 Series GAS Fryers Fryer Operations Pilot Lighting Procedures, Electronic Ignition SystemsBoil-Out Procedure Boil-Out Procedure Final Preparation Filtration Preparation Frymaster FPD65 Series GAS Fryers Filtration OperationAssembling the Filter Frymaster FPD65 Series GAS Fryers Filtration Operation Place the crumb tray in filter pan Filter Leaf Disassembly/Assembly Daily Filtration Operation Cleaning the Filter Leaf AssemblyFiltering Tools Operating the Filter Filter Operation Frymaster FPD65 Series GAS Fryers Filtration Operation Frypot Frymaster FPD65 Series GAS Fryers Filtration Operation Weekly Frymaster FPD65 Series GAS Fryers Preventative MaintenancePeriodic/ Annual Frymaster FPD65 Series GAS Fryers Preventative MaintenanceFrymaster FPD65 Series GAS Fryers Preventative Maintenance Pilot Burner Malfunction Frymaster FPD65 Series GAS Fryers TroubleshootingMain Burner Malfunctions Main Burner Malfunctions HI Limit Diagram, MainFilter Wiring DiagramCabinetry and Related Components Frymaster FPD65 Series GAS Fryers Parts ListFrymaster FPD65 Series GAS Fryers Parts List Doors, Topcaps and Related Components FPD665 ShownFrypots, Burners and Related Components Flue Assembly, Complete CM4-S Component Box ComponentsFilter Pan and Related Components Oil-Drain Components 823-4189 Choose From Nipple Lengths Below Oil-Return ComponentsSuction Tube, Oil-Return Components Oil Suction Start Fitting This page Intentionally Left Blank Service Hotline