Fryer Heating Oil
CONTROLLER
PANEL OPEN
INTERFACE
BOARD VISIBLE
Initiate HEAT MODE by
turning the fyrer on and setting the temperature at least 45° F (24° C) above the temperature of the cooking oil.
Is the HEATING MODE indicator lit with the POWER
indicator on?
NOTE: Indicator may cycle on and off.
YES
Is the
Is the circuit breaker in the
YES
Continued on
next page
NO
NO
1.TROUBLE LIGHT indicates:
a.Oil temperature is higher than 410° F/ 210° C
b.There is a problem in the temperature measuring circuitry, including the probe.
2.HEATING MODE indicator and TROUBLE LIGHT on at the same time indicates a problem with the latching relay on the interface board or the latching contactor.
Probable causes are:
1.Defective controller
2.Broken or improper wire connection
Probable causes are:
1. Unplugged