Frymaster H14 Series service manual M-100B Computer Operating Instructions

Page 13

The fryer has two built-in high-limit protection features. If the temperature in the frypot reaches approximately 410°F (210°C), the computer opens the heat relay circuit, turning the elements off. If the temperature in the frypot reaches 450°F (232°C), a mechanical high-limit shuts off electrical power to the elements. The operator should periodically test each of the high-limit protection features to verify that they are operating correctly. Refer to Grills/Fryers Maintenance Requirement Card (MRC) 15 for the procedure.

3.3M-100B™ Computer Operating Instructions

WARNING

Before pressing the on/off switch to the ON position, ensure that the frypot is

properly filled with vegetable oil. See Section 3.1.

Operating the Computer on Full-Vat Fryers

0.Turn ON the cooking computer by pressing the right ON/OFF switch . A product name (for example, FR FRIES) will appear in the right LED display.

0.If the frypot temperature is below 180°F (82°C), the computer will automatically enter a warm-up cycle (often called a melt cycle). The heating elements will cycle on and off repeatedly, allowing the vegetable oil to heat gradually, without scorching. During the warm-up cycle, the right heating mode indicator will alternately illuminate and go out as the elements cycle on and off. Within about 45 minutes, the computer will exit the warm-up cycle and the heat mode indicator will remain continuously illuminated.

0.The M-100B computer allows the operator to use both sides of the computer if desired. By having both sides of the computer on, the operator can select two products that have the same cooking temperature, but different cooking times. Using a pair of twin baskets, both products can be cooked at the same time.

0.To activate the left side of the computer, press the left ON/OFF switch . A product name will be displayed in the left LED display.

0.Select the product to be cooked by pressing the right product selection switch (or, if both sides of the computer are ON, the left product selection switch ) until the desired product is displayed.

Once the frypot temperature is above 180°F (82°C), but still 15°F (8°C) or more below the setpoint temperature for the product displayed (for example, french fries), the computer will alternately display

LOW TEMP and FR FRIES, and the right heating mode indicator will remain continuously illuminated.

The cooking cycle cannot be started until the cooking oil is within ±15°F (8°C) of the programmed setpoint. When the frypot temperature is within ±15°F (8°C) of the programmed setpoint, the product name will be displayed continuously, indicating that the fryer is ready to cook the displayed product.

3–3

Image 13
Contents Frymaster H14 Series Electric Fryer Computers FCC Warranty Statement Parts Return Introduction Safety InformationGeneral European Community CE Specific Information Computer InformationService Information Shipping Damage Claim ProcedureDo not block the area around the base or under the fryers Installation InstructionsAfter Fryers Are Under The Fry Station Hood Power RequirementsFrypot Boil-Out Operating Fryers With M100B Cooking Computers Equipment Setup and Shutdown ProceduresIntroduction To The M-100B Cooking Computer ShutdownDescription Operating the Computer on Full-Vat Fryers M-100B Computer Operating InstructionsOperating the Computer on Split-Vat Fryers Open Drain Valve Indication M-100B Computer Problem Condition IndicatorsRecovery Out of Range REC LOC How to Enter the Setup Mode 1 M-100B Computer Setup ModeM-100B Computer Set-Up and Programming Instructions How to Configure the Computer for Use on an Electric Fryer How to Change the Computer’s Display LanguageHow to Change Computer Product/Temperature Displays How to Activate or Deactivate the Frypot BOIL-OUT Feature How to Enter the Program Mode 2 M-100B Computer Programming ModeHow to Reset the Computer to the Factory Defaults How to Enter a Product Name in a Test Menu How to Change the Cooking Temperature SetpointPage How to Suppress a Shake, QA, or Duty Function How to Display the Product Cycle Accumulator Information How to Display Use Time InformationHow to Use the Filter Countdown Timer Introduction to the Analog Controller Operating Fryers With Analog ControllersI J K L M N Analog Controller High-Limit Check Analog Controller Operating InstructionsPage Description Function Operating the BUILT-IN Filtration SystemSTEP-BY-STEP Filtration Instructions Page Page Page Page Page Page Page Care and Cleaning of Your Fryer and Filter System Water in the Filter PAN MSDU50 Preventive Maintenance Troubleshooting Preventive Maintenance and TroubleshootingComputer Panel Open Interface Board Visible Computer Panel Open Interface Board Visible Fryer Heating OilFrom Preceeding From Preceeding Is the AL LED illuminated? Controller Panel Open Interface Board Visible From Preceeding From Preceeding Filter System Operation Pump Motor ActuationReplace Controller Service ProceduresReplace Interface Board Replace Transformer Replace Temperature ProbeReplace Temperature Probe Replace Heating Element Replace Heating Element Remove the element mounting screws Left element- 9-pin Right element- 6-pin Connector Replace HIGH-LIMIT Replace Frypot Replace Contactor Contactor mounting screws Filtration Problem Resolution BUILT-IN Filter System Service ProceduresBUILT-IN Filter System Service Procedures FootPrint III Wiring Diagram Diagnostic LED Legend Electric Interface Board Diagnostic ChartCommon Electric McDONALDS H14 SERIES- FULL-VAT Wiring DiagramsSimplified GND Common Electric McDONALDS H14 SERIES- DUAL-VATCommon Electric McDONALDS H14 SERIES- FULL-VAT- Export WYE Common Electric McDONALDS H14 SERIES- DUAL-VAT- Export WYE McDonald’s Domestic Wiring DIAGRAMS, MainMcDonald’s European Community CE McDonald’s European Community CE Prior To 9/98 McDonald’s European Community CE XBIH14 McDonald’s Domestic Contactor McDonald’s European Community CE WYE Contactor McDonald’s European Community CE XBIH14 Contactor McDonald’s 440/480V Contactor McDonald’s Delta CSA Contactor McDonald’s Domestic Control Cord McDonald’s English Control Cord Footprint III, Early Configuration Wiring DIAGRAMS, Filter UnitsFootprint III, Late Configuration Accessories H14 Series Electric Fryers Parts ListPage Side , Cabinet 2 MH/BIH214, 314, 414, 514 Cabinet Assemblies Component Casters, Legs and Associated Hardware Component Box Assemblies/Associated Component Parts Page Control Panel Assembly Door Assembly Components Controller Assemblies Drain System Components Page McDonald’s Domestic, Dual-vat Elements and Related Components Component Hood Relay Box, Power Cords and Hood Cords Filter Base/Pan Assemblies 8.9.1 Filter Base Assemblies Filter Base Assembly, FootPrint Filter Pan Assemblies Filter Pan Assembly, Single FootPrint Filter Pump and Motor Assemblies Pump and Motor Assembly, 250V 50/60 Hz Page Flex Line Assembly, With Male/Female Ends Oil Return Linkage Assemblies and Components Frypot Assemblies and Drain Valve Components Thermostats and Related Components