Fryer Heating Oil
COMPUTER
PANEL OPEN
INTERFACE
BOARD VISIBLE
Initiate HEAT MODE by
turning the fyrer on and setting the temperature at least 45° F (24° C) above the temperature of the cooking oil.
Is the HEATING MODE indicator lit with LOW TEMP
displayed in computer window?
NOTE: Indicator may cycle on and off and LOW TEMP
may alternate with the product name.
YES
Is the
Is the circuit breaker in the
YES
Continued on
next page
NO
NO
1.Product name displayed constantly indicates oil temperature is within 45° F (24° C) of set- point.
2.HOT HI 1 indicates the oil temperature is higher than 410° F/210° C (395° F/202° C for European Community).
3.3. PROBE FAILURE indicates a problem in the
4.IGNITION FAILURE indicates a problem with the latching relay on the interface board or the latching contactor.
Probable causes are:
1.Defective computer
2.Broken or improper wire connection
Probable causes are:
1. Unplugged