4.After the oil has drained from the frypot, turn the filter handle to the ON position to start the pump and begin the filtering process. There may be a slight delay before the pump activates.

Turn filter handle to the ON position

5.The filter pump draws the oil through the filter medium and circulates it back up to and through the frypot during a 5-minute process called polishing. Polishing cleans the oil by trapping solid particles in the filter medium.

6.After the oil is filtered (about 5 minutes), close the drain valve and allow the fryer to refill. Let the filter pump run 10 to 12 seconds after the oil begins to bubble. Turn the filter off.

WARNING

The filter pump is equipped with a manual reset switch in case the filter motor overheats or an electrical fault occurs. If this switch trips, turn off power to the filter system and allow the pump motor to cool 20 minutes before attempting to reset the switch (see photo below).

Filter Pump Reset Switch

7.Lower the elements into the frypot and reinstall the basket support rack.

4-6

Image 20 Contents
Hour Service Hotline Electric Fryers RE SeriesCanada Page Table of Contents General Safety InformationRE Series E4 Electric Fryers Introduction Definitions Computer InformationEuropean Community CE Specific Information Shipping Damage Claim Procedure Service InformationRE Series E4 Electric Fryers Installation Instructions Australian Requirements Power Requirements Three 3 Phase RequirementsPage RE Series E4 Electric Fryers Operating Instructions Finding Your WAY around the Fpre Series E4 Electric FryerShutdown Equipment Setup and Shutdown ProceduresSetup Controllers RE Series E4 Electric Fryers Filtration Instructions Page Preparation for Use with Filter Paper or Filter Pad Preparation for Use with the Magnasol Filter Assembly Page Filter Pump Reset Switch Cleaning Reassembly Draining and Disposing of Waste OilRE Series E4 Electric Fryers Preventative Maintenance Page Annual/Periodic System Inspection FryerBuilt-In Filtration System RE Series E4 Electric Fryers Operator Troubleshooting IntroductionTroubleshooting Controller and Heating Problems Controller wontActivate Fryer does not heatProblem Fryer repeatedlyError Messages and Display Problems Problem Heating mode light Digital controllerDisplay is in wrong Solid state controllerBasket Lift Problems Filtration ProblemsOil occurs But oil return is verySlow and bubbling This page Intentionally Left Blank Service Hotline