Bloomfield WVOC-2HFG, WVOC-2HSG operation manual Ventilator Section, Description Comment

Page 5

 

 

FEATURES & OPERATING CONTROLS (continued)

 

 

VENTILATOR SECTION

 

ITEM

DESCRIPTION

COMMENT

1.

NAMEPLATE

Gives manufacturer, make and model description. Also lists voltage

 

 

and amperage data.

a6.

FIRE SUPPRESSION

Container for Ansulex™ Low-pH liquid fire suppression liquid.

 

AGENT TANK (1.5 gal.)

 

8.

ADJUSTABLE (FRONT) LEG

Allows the unit to be leveled.

9.

RIGID (REAR) CASTER

Allows the unit to be easily positioned by lifting the front of the unit

 

 

slightly.

a10.

MANUAL PULL STATION

Provides a means of manual activation of the fire suppression system.

 

 

PULL ONLY IN CASE OF FIRE!

a11.

FUSIBLE LINKS

Automatically activates fire suppression system in the event of fire on

 

 

the cooktop.

12.

LOWER REAR ACCESS

Allows access to Ansul® fire suppression agent tank (a6) and controls

 

PANEL

also access to main power contactor (41).

a15.

DISCHARGE NOZZLE

Fire suppression media discharges here (2 places).

16.

GREASE BAFFLE

Extracts and drains most grease and moisture from the air flow.

18.

PRE-FILTER ASSEMBLY

Comprises the PRE-FILTER FRAME and a replaceable

 

 

PRE-FILTER. Stops larger particles of grease from reaching the

 

 

FILTER PACK for reduced maintenance costs.

19.

HEPA/CHARCOAL FILTER

Stops most grease and smoke particles. Also assists in some cooking

 

PACK

odor removal.

22.

GREASE CUP

Collects grease/moisture drained from grease trough (23).

23.

GREASE TROUGH

Directs grease/moisture removed by grease baffle to grease cup.

28.

VENTILATOR EXHAUST

Exit point for ventilator airflow - on top left rear of unit.

 

DUCT

DO NOT BLOCK

a31.

STATUS INDICATOR

Displays status of fire suppression system (COCKED - FIRED) If

 

 

FIRED, a buzzer will sound continuously.

38.

POWER CORD

6’ cord and cap. Plug for NEMA 15-60R (receptacle by user).

40.

FUSES

Provide over-current protection.

41.

POWER CONTACTOR

Energizes cooking appliances only while ventilator section is sensed

 

 

as operational.

42.

BUILDING FIRE ALARM

Reports fire alarm condition to building fire management system.

 

RELAY

 

43.

GROUND LUG

Ground wire of power cord connects here.

44.

INTERLOCK TERMINAL

Provides connection for shut-down control by building fire management

 

 

system.

53.

FILTER INTERLOCK

Proper installation of grease baffle and filter pack close these switches

 

SWITCHES

in ventilator sensor circuit.

56.

VENTILATOR FAN

Provides air movement for ventilation.

57.

HOOD SIDE SHIELD

Required on left and right sides of hood. Factory installed.

58.

SIDE SPACERS

Required to maintain 6" spacing from combustibles. Field installed.

3

Image 5
Contents Important do not Discard this Manual 505Limited Warranty Statement Introduction Table of ContentsSpecifications Features & Operating Controls Description Comment Ventilator SectionFeatures & Operating Controls Description Comment Ventilator Section ControlsCooking Appliance Controls Electric Shock hazard Precautions and General InformationSTD Agency Listing InformationOperational Notes Unpacking & Inspection InstallationSetup Electrical Installation Service Technician Installation NotesThis is Responsibility Installer Electric Shock HazardAuthority Having Jurisdiction Fire Suppression System InstallationFire Hazard Filter Installation Filters InstallationHotplate Drip PAN Installation Spiral Heating Elements only Grease Trough and Grease CUP InstallationOven Rack Installation Do not Operate Unless Grease CUP is InstalledOperation Ventilator OperationPRE-FILTER Element Hot SurfaceGriddle Product Temp Time Minutes Suggested Cooking TimesConvection Oven Product Temp Time Number Minutes Racks Program Cook Mode Manual Cook ModeConvection Oven Operating Instructions Electrical Shock HazardGriddle Operating Instructions Temperature Offset ModeBurn Hazard SeasoningCooking with Your Hotplate Hotplate Operating InstructionsConvection Oven Cleaning Instructions Cleaning InstructionsGriddle Exterior Griddle Cleaning InstructionsPrecautions Hotplate Cleaning InstructionsFrequency ToolsCleaning Ventilator Section Cleaning InstructionsPreparation Frequency WeeklyTroubleshooting Suggestions FAN Cleaning Maintenance InstructionsLatch Adjustment Personal Injury HazardHinge Adjustment Maintenance InstructionsTemperature Calibration Ansul Health Hazards Page Page Fire Hazard Maintenance SchedulesDescription Service

WVOC-2HFG, WVOC-2HSG specifications

The Bloomfield WVOC-2HSG and WVOC-2HFG models represent the cutting edge in advanced automation and control systems designed for diverse industrial applications. These systems serve as pivotal tools for optimizing processes, enhancing efficiency, and ensuring precise monitoring of various operations across numerous sectors.

One of the main features of the Bloomfield WVOC-2HSG and WVOC-2HFG is their dual functionality, which allows for simultaneous management of multiple process parameters. The WVOC-2HSG variant is tailored for high-speed data acquisition and processing, making it suitable for environments where real-time monitoring is crucial. In contrast, the WVOC-2HFG offers enhanced flexibility with its feature-rich interface and robust control capabilities, catering to applications that demand customization and adaptability.

Both models leverage advanced technologies such as Internet of Things (IoT) connectivity, enabling seamless integration with existing infrastructure. This connectivity facilitates remote monitoring and control, allowing operators to access data from anywhere, thus improving decision-making and response times. The cloud-based analytics feature further empowers users to generate insights from historical data, leading to better predictions and proactive maintenance strategies.

In terms of characteristics, the Bloomfield WVOC-2HSG and WVOC-2HFG systems come equipped with high-resolution displays and intuitive user interfaces. These interfaces are designed to minimize the learning curve for new users while providing seasoned operators with the tools needed for complex tasks. The systems also include a variety of input and output options, making them compatible with a wide array of sensors and actuators.

Durability is another significant characteristic of these models, as they are engineered to withstand challenging industrial environments. Built with rugged materials, they are resistant to dust, moisture, and extreme temperatures, ensuring reliable performance over time.

Moreover, safety features are seamlessly integrated into these systems, with built-in alarms and redundancy mechanisms designed to prevent operational failures. This commitment to safety underscores Bloomfield's dedication to providing not only performance but also peace of mind for operators.

In conclusion, the Bloomfield WVOC-2HSG and WVOC-2HFG models stand out as premier solutions in industrial automation, showcasing a blend of innovative technology, user-centric design, and enhanced durability. Whether for real-time data processing or flexible control capabilities, these systems are set to redefine standards in operational efficiency and reliability across various industries.