REFRIGERATOR COMPONENTS

1.Door switch: To detect the door status (open/close).

2.Battery switch: ON-OFF switch for built-in battery for power failure alarm. Always turn on this switch when the refrigerator is operated. Turn off this switch when the refrigerator is not used for long period to protect the battery.

3.Power switch: Main switch of the unit.

4.Glow starter: For a fluorescent lamp. It is recommended to replace the glow starter at the time of replacement of fluorescent lamp. Refer to page 21 for the replacement.

5.Control panel: Panel can be opened when upper right corner of the lower part cover is pushed. The running status is displayed on this panel and temperature setting is accomplished through this panel. Refer to page 10 for details.

6.Light switch: This switch is used for turning the fluorescent lamp off and on.

7.Glass window: The window may have condensation in high humidity environment. Wipe off the condensation with a soft dry cloth.

8.Handle: Always hold the handle when opening/closing the door.

9.Lock: Turn the key counterclockwise through 180o to securely lock the door.

10.Fluorescent lamp: 15 W lamp. Normally turn off the lamp. See page 20 for the replacement.

11.Monitor bottle for temperature sensor (2 locations): The bottles has a sensor to display the chamber temperature. Fill the bottle with 200ml of 10% glycerol or water before commencing the operation. Refer to page 13 for filling the monitor bottle.

12.Access port: This port allows temperature measurement cables or sensors to enter the chamber from outside.

13.Shelf (MBR-304D, MBR-304G), Drawer (MBR-304DR, MBR-304GR): Items to be stored in the chamber must be placed on the shelves or drawers. The maximum storage weight for each shelf or drawer is 20 kg. Do not put stored items directly onto the interior floor of the chamber.

14.Condensation tray: The condensation on the door is accumulated in this tray. Wipe off the water occasionally.

15.Caster: Used when moving the unit. When installing the unit the castors can be raised from the ground by using the leveling feet.

16.Leveling foot: Adjust the height of the leveling foot to install the refrigerator in level. See page 12 for details.

17.Automatic temperature recorder: For details, see the instruction manual of the recorder enclosed with the unit.

18.Air exhaust vent: Do not block this vent. Care should be taken not to expose the stored items to direct cooled air.

19.Inner door: Made of acrylic resin. For cleaning, use the diluted neutral dishwashing detergent

20.Air intake vent: Do not block this vent. If this vent is blocked, temperature regulation will become unstable. Do not insert fingers or any substances into the vent because the circulating fan is running inside the vent.

21.Door latch: By turning the latch downward, the door is locked. A padlock can be provided separately.

9

Image 10
Contents MBR-304DR MBR-304GR MBR-304D MBR-304G Contents Precautions for Safe Operation Symbol showsPrecautions for Safe Operation Prevent electric shock or injury Damage Page Environmental Conditions Refrigerator Components Refrigerator Components Control panel and keypad Installation Installation siteInstallation Preparation of monitor bottle Before Commencing OperationLoosen Remote alarm terminal Operation after power failure START-UP of UnitAir-intake vent Operating InstructionsStoring of items Air-exhaust ventCycle defrost Temperature displayDefrost cycles Forced defrostCalibration of temperature sensor Alarms and safety functions Alarms & Safety FunctionsAlarm test procedure Cleaning of cabinet Routine MaintenanceReplacement of fluorescent lamp Cleaning of condenser filter Replacement of glow starterDisposal of Unit Alarm device is activated TroubleshootingIf nothing operates even when switched on When the unit does not get cold enoughSpecifications PerformanceSafety check sheet CEM