UTILITY SERVICE LAYOUT
Gas and electrical services for the Models 1116 and 1117 should be located as shown below. If flexible services are provided, they must meet code requirements for such installation.
Back view of two Impinger® II Gas Ovens showing |
| Back view of three Impinger® II Gas Ovens showing |
Gas Valve Installation and piping spacing. |
| Gas Valve Installation and piping spacing. |
|
|
|
INSTALLATION CODES AND GUIDELINES
GAS INSTALLATION
Safe and satisfactory operation of this oven depends to a great extent upon its proper installation, and it should be installed, as applicable in accordance with the National Fuel Gas Codes, ANSI Z223.1/NFPA 54 latest version, Manufacturers’ Installation Instructions and local municipal building codes, ISO
1.The oven and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.45kPa).
2.The oven must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply system at test pressures equal to or less than ½ psig (3.45kPa).
IN MASSACHUSETTS: The minimum length of a flexible gas supply hose is
IN CANADA: The installation of these appliances is to be in accordance with CSA B.149.1 latest version – Natural Gas and Propane Installation Code – and/or Local Codes.
IN AUSTRALIA: Adhere to AG
10 | Impinger II – Digital Advantage Ops Manual |