Bunn TITAN DUAL manual Procedure for setting the Units

Page 17

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

UNITS

This function allows the operator to select if numeric settings are displayed in English or Metric units.

Procedure for setting the Units:

1.Press and hold the right hidden button until the display reads SET LANGUAGE? Press and release the right hidden button until the display reads UNITS. The METRIC or ENG should be flashing.

2.Select METRIC to have settings displayed in Metric units. Select ENG to have setting displayed in English units.

NOTE: Changing the UNIT settings will restore ALL settings to Factory Default.

3.When done, press DONE to advance to the next programming screen. To exit programming and return to the Main Screen, press and release either ON/OFF button.

NOTE: This manual is written based on Factory Default Settings (English Units). If brewer is set for Metric Units, displays will be different (ex: Brew oz will become Brew ml).

SET LANGUAGE?

 

UNITS

NO

YES

 

METRIC DONE ENG

 

Page 17

40119 071107

 

Image 17
Contents Phone 217 529-6601 FAX 217 Post Office BOX SPRINGFIELD, IllinoisTrademarks of Bunn-O-Matic Corporation BUNN-O-MATIC Commercial Product WarrantyIntroduction ContentsUser Notices Electrical HOOK-UP 400/230V volt ac three phase 50/60 Hz modelsElectrical Requirements Plumbing Requirements CE RequirementsPlumbing Hook UP Tank DrainOperating Controls Tank Filling until tank is filled with water Initial SET-UPViewing Asset & Serial Number Coffee Brewing Cleaning Glossary Programming Section Programming SwitchesProgramming Programming the Brewer Programming Lockout SwitchImportant Programming Notes Read Carefully ScreenProgramming Functions Level Programming the BrewerProgramming Functions Level Brew Lockout Procedure for setting Brew LockoutSET Language Procedure for setting LanguageProgramming the Brewer Programming Functions Level 2 Units Procedure for setting the UnitsSET Temp Ready Temp Procedure to set ready temperature Range 2 to 20 F 2 to 10 CNext Brew SettingsProcedure to set or modify brew volumes. Range 10 to 500 oz Press YES to proceed. The display should now Ton until display reads Brew Settings ?Press and release the right hidden button until Batches DONE? SET Pulse BREW/PREINFUSION Setting Pulse BrewOFF Time XXX Done + Drip Time Review Settings ?LEFT---- Right Are YOU Sure ?Copy Settings ? No YES Range 0 to RefillSpray OZ/M Procedure to adjust the sprayhead flow rate set- tingBypass OZ/M Procedure to adjust the bypass flow rate settingRepeat steps 1-7 to calibrate the other side Procedure to calibrate the sprayhead flow rateCalibrate Flow Repeat steps 1-7 to calibrate the other side Brew Counters Procedure to view/reset the brew countersProcedure to Enable/Disable Ads Enable ADSSAVE? No Edit YES Advertisement Setup Complete Procedure for enabling clean Range 0.0 to 72.0 hrs Enabl CleanDone Enable EnergysavrTimer Enable Fresh Timer Asset Number Procedure to enter the asset numberEnter Asset #? Press and release YES. The display will now readProcedure to enter the service number Service NumberEnter Service #? Service TOOLS?Test Switches Service ToolsProcedure to test components and outputs Service TOOLS? No YES Pressed Left HiddenDone Quency YOU SURE? Factory DefaultsProcedure to set factory defaults Factory Default Values Troubleshooting Problem TroubleshootingProbable Cause RemedyTest switch procedures on Problem Probable Cause RemedyBrew valve Control BoardRefill probe or Sensitivity set LongTing Obstructions. Clear or replace Refill valve If the left three digit numberAutomatic refill will not operate or Problem Probable CauseControl Board ON/OFF Switch Ting Water flows into tank continuously Refill valveTo it is secure Foreign material lodged in valveHeating Time TOO Long No bypass water Bypass valve Test outputs procedures onLime buildup Sprayhead or air ventInconsistent beverage level Improper water pressure Brew volume adjustmentServer/dispenser 90 psi 138 and 620 kPaFor proper extraction Tank heaters Remove and clean lime off tank HeatersSolenoids Vibrate during operationWeak beverage Type of paper filter Water temperatureCoffee Proper extractionSchematic Wiring Diagram Schematic Wiring Diagram Titan Dual CE

TITAN DUAL specifications

The Bunn TITAN DUAL is a commercial coffee brewer designed to deliver high-quality coffee with efficiency and consistency. Made for establishments that prioritize both speed and taste, the TITAN DUAL stands out with a variety of features that enhance its usability and performance.

One of the significant features of the Bunn TITAN DUAL is its dual brewing capability, which allows users to brew two separate batches of coffee simultaneously. This is particularly beneficial for busy cafes and restaurants that need to meet high customer demand during peak hours. The brewer can support various batch sizes, empowering users to customize their brewing to match the needs of their business, whether it’s a quick single cup or several gallons at once.

The Bunn TITAN DUAL employs advanced brewing technology, including NitroCold Brew options that create a smooth, cold coffee with a unique flavor profile. This technology allows for the extraction of rich flavors while maintaining a refreshing finish, catering to modern coffee trends that demand versatility.

Another notable feature is the integrated digital brewing controls. The intuitive interface allows baristas to set precise brew times and temperatures, ensuring that each cup of coffee is consistently high quality. With programmable features, coffee shops can optimize their brewing processes, reducing waste while maximizing flavor.

The TITAN DUAL is designed for ease of maintenance, with removable parts that simplify cleaning and servicing. This ensures that the brewer can remain operational with minimal downtime, an essential aspect for any commercial kitchen environment. The stainless steel construction promises durability, making it an investment that can withstand the rigors of daily use.

Additionally, the Bunn TITAN DUAL reportedly has a high-capacity water tank, which ensures quick recovery time between brews. This feature is crucial during busy service times, as it allows for rapid preparation of coffee without long waiting periods.

With energy efficiency in mind, the brewer is designed to quickly heat water to the optimal temperature. This not only benefits the environment but also helps reduce operating costs over time.

In summary, the Bunn TITAN DUAL is an advanced commercial coffee brewer engineered for speed, efficiency, and quality. Its dual brewing capabilities, advanced technologies, and user-friendly features make it a valuable addition to any coffee-focused business, ensuring that customers receive a consistent and satisfying coffee experience.