Bunn TITAN DUAL manual Long, Refill probe or Sensitivity set, If the left three digit number

Page 49

TROUBLESHOOTING (cont.)

 

 

 

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

Automatic refill will not operate

 

1. No water

Check plumbing and shut-off

or display shows FILL TIME TOO

 

 

 

valves

LONG

 

2. Refill probe or Sensitivity set-

Remove the strainer and check for

 

 

 

 

ting

obstructions. Clear or replace.

 

 

3. Refill valve

Check the sensitivity setting. Refer

 

 

 

 

to the REFILL function on page

 

 

 

 

27. If the left three digit number

 

 

 

 

is less than the right number, the

 

 

 

 

machine “thinks” it is full and the

 

 

 

 

refill valve should be off. If the left

 

 

 

 

number is larger than the right, then

 

 

 

 

the refill valve will automatically be

 

 

 

 

turned on to fill the tank. The right

 

 

 

 

number is the threshold setting and

 

 

 

 

can be adjusted to compensate for

 

 

 

 

extreme water conditions: very pure,

 

 

 

 

low conductance water requires a

 

 

 

 

higher setting, while high mineral

 

 

 

 

content, high conductance water

 

 

 

 

requires a lower setting. Note that

 

 

 

 

the left number changes from a high

 

 

 

 

value when water is NOT touching

 

 

 

 

the refill probe to a low valve when

 

 

 

 

water IS touching the probe. For

 

 

 

 

best operation, the right number

 

 

 

 

should be set to a value midway

 

 

 

 

between these low and high num-

 

 

 

 

bers. Before changing the setting,

 

 

 

 

confirm that the refill probe is free

 

 

 

 

of scale buildup and the connection

 

 

 

 

to it is secure. Test the refill valve.

 

 

 

 

Refer to the test outputs procedures

 

 

 

 

on page 40.

Page 49

40119 071107

 

Image 49
Contents Phone 217 529-6601 FAX 217 Post Office BOX SPRINGFIELD, IllinoisTrademarks of Bunn-O-Matic Corporation BUNN-O-MATIC Commercial Product WarrantyIntroduction ContentsUser Notices Electrical Requirements 400/230V volt ac three phase 50/60 Hz modelsElectrical HOOK-UP Plumbing Requirements CE RequirementsPlumbing Hook UP Tank DrainOperating Controls Viewing Asset & Serial Number Initial SET-UPTank Filling until tank is filled with water Coffee Brewing Cleaning Glossary Programming Programming SwitchesProgramming Section Programming the Brewer Programming Lockout SwitchImportant Programming Notes Read Carefully ScreenProgramming Functions Level Programming the BrewerProgramming Functions Level Brew Lockout Procedure for setting Brew LockoutProgramming the Brewer Programming Functions Level 2 Procedure for setting LanguageSET Language Units Procedure for setting the UnitsSET Temp Ready Temp Procedure to set ready temperature Range 2 to 20 F 2 to 10 CProcedure to set or modify brew volumes. Range 10 to 500 oz Brew SettingsNext Press and release the right hidden button until Ton until display reads Brew Settings ?Press YES to proceed. The display should now Batches DONE? SET Pulse BREW/PREINFUSION Setting Pulse BrewOFF Time XXX Done + Drip Time Review Settings ?LEFT---- Right Are YOU Sure ?Copy Settings ? No YES Range 0 to RefillSpray OZ/M Procedure to adjust the sprayhead flow rate set- tingBypass OZ/M Procedure to adjust the bypass flow rate settingCalibrate Flow Procedure to calibrate the sprayhead flow rateRepeat steps 1-7 to calibrate the other side Repeat steps 1-7 to calibrate the other side Brew Counters Procedure to view/reset the brew countersProcedure to Enable/Disable Ads Enable ADSSAVE? No Edit YES Advertisement Setup Complete Procedure for enabling clean Range 0.0 to 72.0 hrs Enabl CleanTimer Enable EnergysavrDone Enable Fresh Timer Asset Number Procedure to enter the asset numberEnter Asset #? Press and release YES. The display will now readProcedure to enter the service number Service NumberEnter Service #? Service TOOLS?Procedure to test components and outputs Service ToolsTest Switches Service TOOLS? No YES Done Left HiddenPressed Quency Procedure to set factory defaults Factory DefaultsYOU SURE? Factory Default Values Troubleshooting Problem TroubleshootingProbable Cause RemedyTest switch procedures on Problem Probable Cause RemedyBrew valve Control BoardRefill probe or Sensitivity set LongTing Obstructions. Clear or replace Refill valve If the left three digit numberControl Board ON/OFF Switch Problem Probable CauseAutomatic refill will not operate or Ting Water flows into tank continuously Refill valveTo it is secure Foreign material lodged in valveHeating Time TOO Long No bypass water Bypass valve Test outputs procedures onLime buildup Sprayhead or air ventInconsistent beverage level Improper water pressure Brew volume adjustmentServer/dispenser 90 psi 138 and 620 kPaFor proper extraction Tank heaters Remove and clean lime off tank HeatersSolenoids Vibrate during operationWeak beverage Type of paper filter Water temperatureCoffee Proper extractionSchematic Wiring Diagram Schematic Wiring Diagram Titan Dual CE

TITAN DUAL specifications

The Bunn TITAN DUAL is a commercial coffee brewer designed to deliver high-quality coffee with efficiency and consistency. Made for establishments that prioritize both speed and taste, the TITAN DUAL stands out with a variety of features that enhance its usability and performance.

One of the significant features of the Bunn TITAN DUAL is its dual brewing capability, which allows users to brew two separate batches of coffee simultaneously. This is particularly beneficial for busy cafes and restaurants that need to meet high customer demand during peak hours. The brewer can support various batch sizes, empowering users to customize their brewing to match the needs of their business, whether it’s a quick single cup or several gallons at once.

The Bunn TITAN DUAL employs advanced brewing technology, including NitroCold Brew options that create a smooth, cold coffee with a unique flavor profile. This technology allows for the extraction of rich flavors while maintaining a refreshing finish, catering to modern coffee trends that demand versatility.

Another notable feature is the integrated digital brewing controls. The intuitive interface allows baristas to set precise brew times and temperatures, ensuring that each cup of coffee is consistently high quality. With programmable features, coffee shops can optimize their brewing processes, reducing waste while maximizing flavor.

The TITAN DUAL is designed for ease of maintenance, with removable parts that simplify cleaning and servicing. This ensures that the brewer can remain operational with minimal downtime, an essential aspect for any commercial kitchen environment. The stainless steel construction promises durability, making it an investment that can withstand the rigors of daily use.

Additionally, the Bunn TITAN DUAL reportedly has a high-capacity water tank, which ensures quick recovery time between brews. This feature is crucial during busy service times, as it allows for rapid preparation of coffee without long waiting periods.

With energy efficiency in mind, the brewer is designed to quickly heat water to the optimal temperature. This not only benefits the environment but also helps reduce operating costs over time.

In summary, the Bunn TITAN DUAL is an advanced commercial coffee brewer engineered for speed, efficiency, and quality. Its dual brewing capabilities, advanced technologies, and user-friendly features make it a valuable addition to any coffee-focused business, ensuring that customers receive a consistent and satisfying coffee experience.