Bunn TITAN DUAL manual Calibrate Flow, Procedure to calibrate the sprayhead flow rate

Page 30

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

CALIBRATE FLOW

This function allows the operator to enter the actual flow rate of the sprayhead and the bypass for each side of the brewer by dispensing both separately for one minute. The volumes are then entered into the brewer.

Procedure to calibrate the sprayhead flow rate:

1.Place a container, accurately graduated and with a minimum capacity of 60 ounces, beneath the fun- nel.

2.Press and hold the right hidden button until the display reads SET LANGUAGE. Press the right hidden button until the display reads CALIBRATE FLOW.

3.Press and release YES to advance to the SPRAY HEAD CAL function screen. (Pressing NO in the CALIBRATE FLOW screen will advance to the next function screen, BREW COUNTERS).

4.Press and release the YES pad. The display should read CONTAINER READY? If the container is under the funnel, press YES.

5.The display should read CALIBRATE SPRAY. Press and release any BREW button on the side to be cali- brated to begin the sprayhead flow for calibration. The display should read CALIBRATE SPRAY...60 SEC TO FINISH. The 60-second timer on the display will count down to zero. When the counter reaches zero, the display will change to LEFT or RIGHT OZ, along with a number.

6.Measure the amount of water in the container and use the (-)and (+) pads to adjust the amount of the display to match the amount in the container. Then press DONE.

7.The display should now read NEW L or NEW R SPRY FLOW, along with the correct flow rate of the sprayhead. After about 5 seconds, the display will return to the CALIBRATE FLOW screen.

8.Repeat steps 1-7 to calibrate the other side.

9.To exit the CALIBRATE FLOW function and advance to the next function screen, press and release NO. To exit programming, press and release either ON/OFF button to return to the MAIN SCREEN.

CALIBRATE FLOW?

NO YES

PRESSING NO WILL

ADVANCE TO

BREW COUNTERS

SPRAYHEAD CAL

NO YES

PRESSING NO WILL

ADVANCE TO

BREW COUNTERS

CONTAINER READY?

QUIT YES

CALIBRATE SPRAY

PRESS BREW START

CALIBRATE SPRAY 60 SEC TO FINISH

LEFT OZ XX.X (-) DONE (+)

NEW L SPRY FLOW

XX.X OZM

5 sec

CALIBRATE FLOW?

NO YES

Page 30

40119 071107

 

Image 30
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Trademarks of Bunn-O-Matic CorporationContents IntroductionUser Notices 400/230V volt ac three phase 50/60 Hz models Electrical RequirementsElectrical HOOK-UP Plumbing Hook UP CE RequirementsPlumbing Requirements Tank DrainOperating Controls Initial SET-UP Viewing Asset & Serial NumberTank Filling until tank is filled with water Coffee Brewing Cleaning Glossary Programming Switches ProgrammingProgramming Section Important Programming Notes Read Carefully Programming Lockout SwitchProgramming the Brewer ScreenProgramming the Brewer Programming Functions LevelProcedure for setting Brew Lockout Programming Functions Level Brew LockoutProcedure for setting Language Programming the Brewer Programming Functions Level 2SET Language Procedure for setting the Units UnitsSET Temp Procedure to set ready temperature Range 2 to 20 F 2 to 10 C Ready TempBrew Settings Procedure to set or modify brew volumes. Range 10 to 500 ozNext Ton until display reads Brew Settings ? Press and release the right hidden button untilPress YES to proceed. The display should now Batches DONE? Setting Pulse Brew SET Pulse BREW/PREINFUSIONOFF Time XXX Done + LEFT---- Right Review Settings ?Drip Time Are YOU Sure ?Copy Settings ? No YES Refill Range 0 toProcedure to adjust the sprayhead flow rate set- ting Spray OZ/MProcedure to adjust the bypass flow rate setting Bypass OZ/MProcedure to calibrate the sprayhead flow rate Calibrate FlowRepeat steps 1-7 to calibrate the other side Repeat steps 1-7 to calibrate the other side Procedure to view/reset the brew counters Brew CountersEnable ADS Procedure to Enable/Disable AdsSAVE? No Edit YES Advertisement Setup Complete Enabl Clean Procedure for enabling clean Range 0.0 to 72.0 hrsEnable Energysavr TimerDone Enable Fresh Timer Enter Asset #? Procedure to enter the asset numberAsset Number Press and release YES. The display will now readEnter Service #? Service NumberProcedure to enter the service number Service TOOLS?Service Tools Procedure to test components and outputsTest Switches Service TOOLS? No YES Left Hidden DonePressed Quency Factory Defaults Procedure to set factory defaultsYOU SURE? Factory Default Values Troubleshooting Probable Cause TroubleshootingProblem RemedyBrew valve Problem Probable Cause RemedyTest switch procedures on Control BoardTing Obstructions. Clear or replace Refill valve LongRefill probe or Sensitivity set If the left three digit numberProblem Probable Cause Control Board ON/OFF SwitchAutomatic refill will not operate or To it is secure Water flows into tank continuously Refill valveTing Foreign material lodged in valveHeating Time TOO Long Lime buildup Test outputs procedures onNo bypass water Bypass valve Sprayhead or air ventServer/dispenser Brew volume adjustmentInconsistent beverage level Improper water pressure 90 psi 138 and 620 kPaSolenoids Tank heaters Remove and clean lime off tank HeatersFor proper extraction Vibrate during operationCoffee Water temperatureWeak beverage Type of paper filter Proper extractionSchematic Wiring Diagram Schematic Wiring Diagram Titan Dual CE

TITAN DUAL specifications

The Bunn TITAN DUAL is a commercial coffee brewer designed to deliver high-quality coffee with efficiency and consistency. Made for establishments that prioritize both speed and taste, the TITAN DUAL stands out with a variety of features that enhance its usability and performance.

One of the significant features of the Bunn TITAN DUAL is its dual brewing capability, which allows users to brew two separate batches of coffee simultaneously. This is particularly beneficial for busy cafes and restaurants that need to meet high customer demand during peak hours. The brewer can support various batch sizes, empowering users to customize their brewing to match the needs of their business, whether it’s a quick single cup or several gallons at once.

The Bunn TITAN DUAL employs advanced brewing technology, including NitroCold Brew options that create a smooth, cold coffee with a unique flavor profile. This technology allows for the extraction of rich flavors while maintaining a refreshing finish, catering to modern coffee trends that demand versatility.

Another notable feature is the integrated digital brewing controls. The intuitive interface allows baristas to set precise brew times and temperatures, ensuring that each cup of coffee is consistently high quality. With programmable features, coffee shops can optimize their brewing processes, reducing waste while maximizing flavor.

The TITAN DUAL is designed for ease of maintenance, with removable parts that simplify cleaning and servicing. This ensures that the brewer can remain operational with minimal downtime, an essential aspect for any commercial kitchen environment. The stainless steel construction promises durability, making it an investment that can withstand the rigors of daily use.

Additionally, the Bunn TITAN DUAL reportedly has a high-capacity water tank, which ensures quick recovery time between brews. This feature is crucial during busy service times, as it allows for rapid preparation of coffee without long waiting periods.

With energy efficiency in mind, the brewer is designed to quickly heat water to the optimal temperature. This not only benefits the environment but also helps reduce operating costs over time.

In summary, the Bunn TITAN DUAL is an advanced commercial coffee brewer engineered for speed, efficiency, and quality. Its dual brewing capabilities, advanced technologies, and user-friendly features make it a valuable addition to any coffee-focused business, ensuring that customers receive a consistent and satisfying coffee experience.