Bunn TITAN DUAL Brew Settings, Procedure to set or modify brew volumes. Range 10 to 500 oz, Next

Page 20

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

BREW SETTINGS

This function allows the operator to modify the BREW VOLUMES, BYPASS PERCENTAGES and BREW METER for each batch size of both brew stations.

Procedure to set or modify brew volumes. Range: 10 to 500 oz.

1.Press and hold the right hidden button until display reads SET LANGUAGE. Press the right hidden but- ton until display reads BREW SETTINGS ?.

2.Press YES to proceed. The display should now read LEFT SIDE, along with MODIFY, SHOW and

NEXT.

3.Press and release MODIFY. The display should read L BREW OZ XXX.X: and a batch light will be

blinking.

4. Using (-)and (+), set the amount of brew water, in ounces, to be dispensed over the grounds for that particular batch size.

5.When finished, press the other batch size and repeat step 4.

6.When finished setting both batch sizes, press DONE. The display should read 2 BATCH SIZES DONE?

7.If both batch sizes are not correct, press NO to return to the L BREW OZ setup screen and repeat steps 4, 5 and 6.

8.If both batch sizes are correct, press YES. This will advance to the % BYPASS function. Another alternative is to press and release either ON/OFF button to exit the BREW OZ setup and return to the

MAIN SCREEN.

BREW SETTINGS ?

NO YES

PRESSING NO WILL

LEFT SIDE

ADVANCE TO NEXT

 

FUNCTION SCREEN

MODIFY SHOW NEXT

 

SET BOTH

L BREW OZ XXX.X

(-) DONE (+)

BATCH SIZES

2 BATCHES DONE ?

NO YES

% BYPASS XXX.X (-) DONE (+)

Page 20

40119 071107

 

Image 20
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Trademarks of Bunn-O-Matic CorporationContents IntroductionUser Notices Electrical HOOK-UP 400/230V volt ac three phase 50/60 Hz modelsElectrical Requirements CE Requirements Plumbing RequirementsPlumbing Hook UP Tank DrainOperating Controls Tank Filling until tank is filled with water Initial SET-UPViewing Asset & Serial Number Coffee Brewing Cleaning Glossary Programming Section Programming SwitchesProgramming Programming Lockout Switch Programming the BrewerImportant Programming Notes Read Carefully ScreenProgramming the Brewer Programming Functions LevelProcedure for setting Brew Lockout Programming Functions Level Brew LockoutSET Language Procedure for setting LanguageProgramming the Brewer Programming Functions Level 2 Procedure for setting the Units UnitsSET Temp Procedure to set ready temperature Range 2 to 20 F 2 to 10 C Ready TempNext Brew SettingsProcedure to set or modify brew volumes. Range 10 to 500 oz Press YES to proceed. The display should now Ton until display reads Brew Settings ?Press and release the right hidden button until Batches DONE? Setting Pulse Brew SET Pulse BREW/PREINFUSIONOFF Time XXX Done + Review Settings ? Drip TimeLEFT---- Right Are YOU Sure ?Copy Settings ? No YES Refill Range 0 toProcedure to adjust the sprayhead flow rate set- ting Spray OZ/MProcedure to adjust the bypass flow rate setting Bypass OZ/MRepeat steps 1-7 to calibrate the other side Procedure to calibrate the sprayhead flow rateCalibrate Flow Repeat steps 1-7 to calibrate the other side Procedure to view/reset the brew counters Brew CountersEnable ADS Procedure to Enable/Disable AdsSAVE? No Edit YES Advertisement Setup Complete Enabl Clean Procedure for enabling clean Range 0.0 to 72.0 hrsDone Enable EnergysavrTimer Enable Fresh Timer Procedure to enter the asset number Asset NumberEnter Asset #? Press and release YES. The display will now readService Number Procedure to enter the service numberEnter Service #? Service TOOLS?Test Switches Service ToolsProcedure to test components and outputs Service TOOLS? No YES Pressed Left HiddenDone Quency YOU SURE? Factory DefaultsProcedure to set factory defaults Factory Default Values Troubleshooting Troubleshooting ProblemProbable Cause RemedyProblem Probable Cause Remedy Test switch procedures onBrew valve Control BoardLong Refill probe or Sensitivity setTing Obstructions. Clear or replace Refill valve If the left three digit numberAutomatic refill will not operate or Problem Probable CauseControl Board ON/OFF Switch Water flows into tank continuously Refill valve TingTo it is secure Foreign material lodged in valveHeating Time TOO Long Test outputs procedures on No bypass water Bypass valveLime buildup Sprayhead or air ventBrew volume adjustment Inconsistent beverage level Improper water pressureServer/dispenser 90 psi 138 and 620 kPaTank heaters Remove and clean lime off tank Heaters For proper extractionSolenoids Vibrate during operationWater temperature Weak beverage Type of paper filterCoffee Proper extractionSchematic Wiring Diagram Schematic Wiring Diagram Titan Dual CE

TITAN DUAL specifications

The Bunn TITAN DUAL is a commercial coffee brewer designed to deliver high-quality coffee with efficiency and consistency. Made for establishments that prioritize both speed and taste, the TITAN DUAL stands out with a variety of features that enhance its usability and performance.

One of the significant features of the Bunn TITAN DUAL is its dual brewing capability, which allows users to brew two separate batches of coffee simultaneously. This is particularly beneficial for busy cafes and restaurants that need to meet high customer demand during peak hours. The brewer can support various batch sizes, empowering users to customize their brewing to match the needs of their business, whether it’s a quick single cup or several gallons at once.

The Bunn TITAN DUAL employs advanced brewing technology, including NitroCold Brew options that create a smooth, cold coffee with a unique flavor profile. This technology allows for the extraction of rich flavors while maintaining a refreshing finish, catering to modern coffee trends that demand versatility.

Another notable feature is the integrated digital brewing controls. The intuitive interface allows baristas to set precise brew times and temperatures, ensuring that each cup of coffee is consistently high quality. With programmable features, coffee shops can optimize their brewing processes, reducing waste while maximizing flavor.

The TITAN DUAL is designed for ease of maintenance, with removable parts that simplify cleaning and servicing. This ensures that the brewer can remain operational with minimal downtime, an essential aspect for any commercial kitchen environment. The stainless steel construction promises durability, making it an investment that can withstand the rigors of daily use.

Additionally, the Bunn TITAN DUAL reportedly has a high-capacity water tank, which ensures quick recovery time between brews. This feature is crucial during busy service times, as it allows for rapid preparation of coffee without long waiting periods.

With energy efficiency in mind, the brewer is designed to quickly heat water to the optimal temperature. This not only benefits the environment but also helps reduce operating costs over time.

In summary, the Bunn TITAN DUAL is an advanced commercial coffee brewer engineered for speed, efficiency, and quality. Its dual brewing capabilities, advanced technologies, and user-friendly features make it a valuable addition to any coffee-focused business, ensuring that customers receive a consistent and satisfying coffee experience.