Bunn TITAN DUAL manual Programming the Brewer Programming Functions Level 2, SET Language

Page 16

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

The functions in the second level of programming allow the operator to adjust brew settings and other feature options.

To access the level 2 function screens press and hold the right hidden button for approximately 5 seconds. Release when the display reads:

SET LANGUAGE

This function allows the operator to select the language used for the display.

Procedure for setting Language:

1.Press and hold the right hidden button until the display reads SET LANGUAGE? and release.

2.Press YES to proceed. The display should now read ENGLISH. Using (-)and (+), scroll through the available languages until the desired language is shown on the display.

3.When finished, press SELECT. If the language selected is different from the current settings,the display will read CHANGE LANGUAGE? ARE YOU SURE? and then will change to CHANGE LANGUAGE? To convert the display to the new language, press YES. To retain the current language, press NO.

4.The display should now read UNITS. To exit programming and return to the MAIN SCREEN, press and release either ON/OFF button.

SET LANGUAGE?

NO YES

ENGLISH

(-) SELECT (+)

UNITS

METRIC DONE ENG

ESPANOL

(-) SELECCIONE (+)

Scrolls through all available languages in memory

Page 16

3811240119. 071421075

 

Image 16
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Trademarks of Bunn-O-Matic CorporationContents IntroductionUser Notices Electrical Requirements 400/230V volt ac three phase 50/60 Hz modelsElectrical HOOK-UP CE Requirements Plumbing RequirementsPlumbing Hook UP Tank DrainOperating Controls Viewing Asset & Serial Number Initial SET-UPTank Filling until tank is filled with water Coffee Brewing Cleaning Glossary Programming Programming SwitchesProgramming Section Programming Lockout Switch Programming the BrewerImportant Programming Notes Read Carefully ScreenProgramming the Brewer Programming Functions LevelProcedure for setting Brew Lockout Programming Functions Level Brew LockoutProgramming the Brewer Programming Functions Level 2 Procedure for setting LanguageSET Language Procedure for setting the Units UnitsSET Temp Procedure to set ready temperature Range 2 to 20 F 2 to 10 C Ready TempProcedure to set or modify brew volumes. Range 10 to 500 oz Brew SettingsNext Press and release the right hidden button until Ton until display reads Brew Settings ?Press YES to proceed. The display should now Batches DONE? Setting Pulse Brew SET Pulse BREW/PREINFUSIONOFF Time XXX Done + Review Settings ? Drip TimeLEFT---- Right Are YOU Sure ?Copy Settings ? No YES Refill Range 0 toProcedure to adjust the sprayhead flow rate set- ting Spray OZ/MProcedure to adjust the bypass flow rate setting Bypass OZ/MCalibrate Flow Procedure to calibrate the sprayhead flow rateRepeat steps 1-7 to calibrate the other side Repeat steps 1-7 to calibrate the other side Procedure to view/reset the brew counters Brew CountersEnable ADS Procedure to Enable/Disable AdsSAVE? No Edit YES Advertisement Setup Complete Enabl Clean Procedure for enabling clean Range 0.0 to 72.0 hrsTimer Enable EnergysavrDone Enable Fresh Timer Procedure to enter the asset number Asset NumberEnter Asset #? Press and release YES. The display will now readService Number Procedure to enter the service numberEnter Service #? Service TOOLS?Procedure to test components and outputs Service ToolsTest Switches Service TOOLS? No YES Done Left HiddenPressed Quency Procedure to set factory defaults Factory DefaultsYOU SURE? Factory Default Values Troubleshooting Troubleshooting ProblemProbable Cause RemedyProblem Probable Cause Remedy Test switch procedures onBrew valve Control BoardLong Refill probe or Sensitivity setTing Obstructions. Clear or replace Refill valve If the left three digit numberControl Board ON/OFF Switch Problem Probable CauseAutomatic refill will not operate or Water flows into tank continuously Refill valve TingTo it is secure Foreign material lodged in valveHeating Time TOO Long Test outputs procedures on No bypass water Bypass valveLime buildup Sprayhead or air ventBrew volume adjustment Inconsistent beverage level Improper water pressureServer/dispenser 90 psi 138 and 620 kPaTank heaters Remove and clean lime off tank Heaters For proper extractionSolenoids Vibrate during operationWater temperature Weak beverage Type of paper filterCoffee Proper extractionSchematic Wiring Diagram Schematic Wiring Diagram Titan Dual CE

TITAN DUAL specifications

The Bunn TITAN DUAL is a commercial coffee brewer designed to deliver high-quality coffee with efficiency and consistency. Made for establishments that prioritize both speed and taste, the TITAN DUAL stands out with a variety of features that enhance its usability and performance.

One of the significant features of the Bunn TITAN DUAL is its dual brewing capability, which allows users to brew two separate batches of coffee simultaneously. This is particularly beneficial for busy cafes and restaurants that need to meet high customer demand during peak hours. The brewer can support various batch sizes, empowering users to customize their brewing to match the needs of their business, whether it’s a quick single cup or several gallons at once.

The Bunn TITAN DUAL employs advanced brewing technology, including NitroCold Brew options that create a smooth, cold coffee with a unique flavor profile. This technology allows for the extraction of rich flavors while maintaining a refreshing finish, catering to modern coffee trends that demand versatility.

Another notable feature is the integrated digital brewing controls. The intuitive interface allows baristas to set precise brew times and temperatures, ensuring that each cup of coffee is consistently high quality. With programmable features, coffee shops can optimize their brewing processes, reducing waste while maximizing flavor.

The TITAN DUAL is designed for ease of maintenance, with removable parts that simplify cleaning and servicing. This ensures that the brewer can remain operational with minimal downtime, an essential aspect for any commercial kitchen environment. The stainless steel construction promises durability, making it an investment that can withstand the rigors of daily use.

Additionally, the Bunn TITAN DUAL reportedly has a high-capacity water tank, which ensures quick recovery time between brews. This feature is crucial during busy service times, as it allows for rapid preparation of coffee without long waiting periods.

With energy efficiency in mind, the brewer is designed to quickly heat water to the optimal temperature. This not only benefits the environment but also helps reduce operating costs over time.

In summary, the Bunn TITAN DUAL is an advanced commercial coffee brewer engineered for speed, efficiency, and quality. Its dual brewing capabilities, advanced technologies, and user-friendly features make it a valuable addition to any coffee-focused business, ensuring that customers receive a consistent and satisfying coffee experience.