Bunn TITAN DUAL manual Batches DONE?

Page 22

PROGRAMMING THE BREWER (cont.)

PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)

BREW SETTINGS (cont.)

Procedure to set or modify BREW METER. Range: 1 to 14 for both batch sizes

NOTE: Using BREW METER will overwrite PULSE BREW settings.

BREW SETTINGS ?

NO YES

PRESSING NO WILL

LEFT SIDE

ADVANCE TO NEXT

 

FUNCTION SCREEN

MODIFY SHOW NEXT

 

This function allows the operator to program the brewer to a non-pulsed brew cycle (setting 1), or to “pulse” the sprayhead flow on and off during a brew cycle (start and stop the flow of water out of the sprayhead). Settings 2 thru 14 will produce pulsed brew cycles to increase the brew strenght with 14 being the highest.

SET BOTH

BATCH SIZES

PRESS AND RELEASE

RIGHT HIDDEN SWITCH

UNTIL DISPLAY READS:

L BREW METER X

- I+

1.Press and hold the right hidden button until display reads SET LANGUAGE. Press the right hidden but- ton until display reads BREW SETTINGS ?.

2.Press YES to proceed. The display should now read LEFT SIDE, along with MODIFY, SHOW and

NEXT.

3.Press and release the right hidden button until display reads L BREW METER. A batch light will be blinking.

4. Using (-)and (+), set the brew meter time for that particular batch size.

5.When finished, press the other batch size and repeat step 4.

6.When finished setting both batch sizes, press center program button (Brewer). The display should read

2 BATCHES DONE?

7.If both batch sizes are not correct, press NO to return to the L BREW METER: setup screen and repeat steps 4, 5 and 6.

8.If both batch sizes are correct, press YES. This will advance to SET PULSE BREW. To exit to the MAIN SCREEN, press and release either ON/OFF button.

SET PULSE BREW

NO YES

Page 22

40119 071107

 

Image 22
Contents Post Office BOX SPRINGFIELD, Illinois Phone 217 529-6601 FAX 217BUNN-O-MATIC Commercial Product Warranty Trademarks of Bunn-O-Matic CorporationContents IntroductionUser Notices Electrical Requirements 400/230V volt ac three phase 50/60 Hz modelsElectrical HOOK-UP Plumbing Hook UP CE RequirementsPlumbing Requirements Tank DrainOperating Controls Viewing Asset & Serial Number Initial SET-UPTank Filling until tank is filled with water Coffee Brewing Cleaning Glossary Programming Programming SwitchesProgramming Section Important Programming Notes Read Carefully Programming Lockout SwitchProgramming the Brewer ScreenProgramming the Brewer Programming Functions LevelProcedure for setting Brew Lockout Programming Functions Level Brew LockoutProgramming the Brewer Programming Functions Level 2 Procedure for setting LanguageSET Language Procedure for setting the Units UnitsSET Temp Procedure to set ready temperature Range 2 to 20 F 2 to 10 C Ready TempProcedure to set or modify brew volumes. Range 10 to 500 oz Brew SettingsNext Press and release the right hidden button until Ton until display reads Brew Settings ?Press YES to proceed. The display should now Batches DONE? Setting Pulse Brew SET Pulse BREW/PREINFUSIONOFF Time XXX Done + LEFT---- Right Review Settings ?Drip Time Are YOU Sure ?Copy Settings ? No YES Refill Range 0 toProcedure to adjust the sprayhead flow rate set- ting Spray OZ/MProcedure to adjust the bypass flow rate setting Bypass OZ/MCalibrate Flow Procedure to calibrate the sprayhead flow rateRepeat steps 1-7 to calibrate the other side Repeat steps 1-7 to calibrate the other side Procedure to view/reset the brew counters Brew CountersEnable ADS Procedure to Enable/Disable AdsSAVE? No Edit YES Advertisement Setup Complete Enabl Clean Procedure for enabling clean Range 0.0 to 72.0 hrsTimer Enable EnergysavrDone Enable Fresh Timer Enter Asset #? Procedure to enter the asset numberAsset Number Press and release YES. The display will now readEnter Service #? Service NumberProcedure to enter the service number Service TOOLS?Procedure to test components and outputs Service ToolsTest Switches Service TOOLS? No YES Done Left HiddenPressed Quency Procedure to set factory defaults Factory DefaultsYOU SURE? Factory Default Values Troubleshooting Probable Cause TroubleshootingProblem RemedyBrew valve Problem Probable Cause RemedyTest switch procedures on Control BoardTing Obstructions. Clear or replace Refill valve LongRefill probe or Sensitivity set If the left three digit numberControl Board ON/OFF Switch Problem Probable CauseAutomatic refill will not operate or To it is secure Water flows into tank continuously Refill valveTing Foreign material lodged in valveHeating Time TOO Long Lime buildup Test outputs procedures onNo bypass water Bypass valve Sprayhead or air ventServer/dispenser Brew volume adjustmentInconsistent beverage level Improper water pressure 90 psi 138 and 620 kPaSolenoids Tank heaters Remove and clean lime off tank HeatersFor proper extraction Vibrate during operationCoffee Water temperatureWeak beverage Type of paper filter Proper extractionSchematic Wiring Diagram Schematic Wiring Diagram Titan Dual CE

TITAN DUAL specifications

The Bunn TITAN DUAL is a commercial coffee brewer designed to deliver high-quality coffee with efficiency and consistency. Made for establishments that prioritize both speed and taste, the TITAN DUAL stands out with a variety of features that enhance its usability and performance.

One of the significant features of the Bunn TITAN DUAL is its dual brewing capability, which allows users to brew two separate batches of coffee simultaneously. This is particularly beneficial for busy cafes and restaurants that need to meet high customer demand during peak hours. The brewer can support various batch sizes, empowering users to customize their brewing to match the needs of their business, whether it’s a quick single cup or several gallons at once.

The Bunn TITAN DUAL employs advanced brewing technology, including NitroCold Brew options that create a smooth, cold coffee with a unique flavor profile. This technology allows for the extraction of rich flavors while maintaining a refreshing finish, catering to modern coffee trends that demand versatility.

Another notable feature is the integrated digital brewing controls. The intuitive interface allows baristas to set precise brew times and temperatures, ensuring that each cup of coffee is consistently high quality. With programmable features, coffee shops can optimize their brewing processes, reducing waste while maximizing flavor.

The TITAN DUAL is designed for ease of maintenance, with removable parts that simplify cleaning and servicing. This ensures that the brewer can remain operational with minimal downtime, an essential aspect for any commercial kitchen environment. The stainless steel construction promises durability, making it an investment that can withstand the rigors of daily use.

Additionally, the Bunn TITAN DUAL reportedly has a high-capacity water tank, which ensures quick recovery time between brews. This feature is crucial during busy service times, as it allows for rapid preparation of coffee without long waiting periods.

With energy efficiency in mind, the brewer is designed to quickly heat water to the optimal temperature. This not only benefits the environment but also helps reduce operating costs over time.

In summary, the Bunn TITAN DUAL is an advanced commercial coffee brewer engineered for speed, efficiency, and quality. Its dual brewing capabilities, advanced technologies, and user-friendly features make it a valuable addition to any coffee-focused business, ensuring that customers receive a consistent and satisfying coffee experience.