Bunn S/N DUAL068000 manual Glossary

Page 9

GLOSSARY

AD CARD: An assembly consisting of a computer chip and an instruction label. Used for loading advertising messages into the brewer.

BREW LOCKOUT: The inability to initiate a brew if the water temperature is less than the ready temperature programmed into the brewer.

BYPASS: The process of diverting a portion of the brew water to the outside of the paper filter so that it does not pass through the coffee grounds. This process is sometimes used to optimize the flavor of the finished brew.

CHIP: A computer chip containing either recipes for specific coffee flavors or advertising messages which are read by the sensing coils on the brewer. One chip is embedded in each Smart Funnel handle to carry the coffee flavor name and batch size ground from the grinder to the brewer.

CYCLE TIME: The total length of time to complete a brew cycle. Does not include Drip Time.

DRIP TIME: The length of time from when the water spray over the grounds ends, to the time that no water drips from the funnel tip.

FACTORY DEFAULTS: The factory preset brew settings that were installed into the brewer's memory.

FIRST ON-TIME:During a pulse brew or preinfusion, this is the time set for the initial flow of water over the grounds.

FUNNEL DETECT: Sets the inability to initiate a brew cycle if the funnel is not properly inserted into the funnel rails.

FUNNEL SENSING COIL: A sensor on the front hood of the brewer, which reads what name and batch size of coffee was ground into the funnel and allows for the brewer to automatically set itself to what is read from the funnel handle.

LAST ON-TIME:During a pulse brew, this is the time set for the second on-time, and each alternating on-time for the remainder of the brew cycle.

MAIN SCREEN: The term used to describe the screen that is displayed when the brewer is not in use. This screen is also displayed after exiting the programming mode.

NO-NAME COFFEE: The term for the recipe used by the brewer when there is no coffee name stored in the funnel. The brewer can contain separate No-Name recipes for the left and right brewing positions.

OFF-TIME:During a pulse brew or preinfusion, this is the time set for the length of time that the water is not spraying over the grounds.

PREINFUSION: The process of beginning a brewing cycle with an initial spray of water onto the grounds followed by a pause in the spray. After the programmed pause, the spray continues without interruption until the end of the brewing cycle.

PULSE BREW: The process which allows the brew water to start, then stop, repeatedly, over the grounds in order to derive the best flavor from the coffee. Pulse brew is also used in some instances to prevent a funnel overflow.

RECIPE: Set of brewing parameters stored in the brewer. The parameters are unique for each coffee name and include brew ounces, pulse brew, percent bypass, preinfusion and drip time.

RECIPE CARD: An assembly consisting of a computer chip and an instruction label. Used for loading a recipe into the brewer and the companion BrewWISE Grinder.

SERVER DETECT: Sets the inability to initiate a brew cycle if the server is not properly placed on the stand below the brew funnel.

SOFT HEAT: The type of server and brewer which are used as part of the Smart Funnel system. The server is placed on the brewer, and is connected through the receptacles on the brewer. The server contains a tem- perature-controlled heater which maintains the coffee at a constant temperature.

Page 9

29877-3 062005

 

Image 9
Contents Phone 217 529-6601 FAX 217 Dual SH DBCIntroduction BUNN-O-MATIC Commercial Product WarrantyTable of Contents 00658.0000 User Notices00831.0000 00656.0000 37881.0000 03408.0004230 volt ac models Electrical RequirementsCE Requirements Plumbing RequirementsPlumbing HOOK-UP Operating Controls Initial Setup CleaningCoffee Brewing Glossary Programming Programming SwitchesProgramming the Brewer Important Programming Notes Read CarefullyProgram Functions Level Not using a Smart Funnel and/or a G9-2T DBC or MHG Grinder Using a Smart Funnel and a G9-2T DBC or MHG GrinderRecipe Programing Methods RecipesContinue To E To D LevelReturns To aProgram Flow Diagram Continue to B Return to aContinue to F Left Brew Valve Byps OZ/M Procedure for modifying units of measure Units Setting Units of MeasureProcedure for Setting the Recipe SET NEW RecipeThis function allows the operator to set Brew Sizes DONE? SET NEW RecipeSET NEW Recipes Procedure to program the coffee nameRight Otherwise, press Next to display no NameProcedure for reviewing recipes Review RECIPES/MODIFY RECIPES/SET UP no Name CoffeeTimes Review RecipesDone Coffee Name Modifyshownext Batches DONE? YES Brew OZ Setting or Adjusting Brew VOL- UmesBatches DONE? BypassModifying pulse brew SET Pulse BrewSET Pulse Brew NO-NAME Left ModifyshownextSET Pulse Brew Easy Pulse Setup SET Pulse Brew Enter Times TIMES?DONE? SET Preinfusion Setup Complete Procedure to modify drip timesDrip Time now displayed on non funnel lock units as well Read % BypassReads Copy Settings Procedure to copy settingsAssign Recipes OnlyYOU SURE? Enable ADS?Are YOU SURE? SET TempSET Temp Procedure to set ready temperatureRefill Range 20 to SET ReadyProcedures to calibrate the sprayhead flow rate Spray OZ/M Procedure to adjust the flow rate settingBypass OZ/M Calibrate FlowProcedures to calibrate the bypass flow rate Repeat steps 1 8 when calibrating the other sideRepeat steps 1 9 when calibrating the other side Calibrate FlowProcedures to view/reset the brew counters Not resettableBrew Counters This function allows the operator to trackFunnel Detect Server DetectServer not in Place Testing individual components outputs Service ToolsProcedure to test switches Service Tools Procedure to test components outputsLeft Brew Valve Nothing PressedProcedures to test servers Service ToolsProcedures to test coil frequency ERS?Procedure to set factory defaults Factory DefaultsTroubleshooting Disable the Server Detect func- tionScreen Displayed Possible Cause Troubleshooting Procedures TemperatureScreen Displayed Smart Funnel not fully inserted into the funnel railsTank Heater failure Triac FailureControl Board/Thermistor failure Troubleshooting Equipment will not operate No power or incorrect voltage Problem Possible Cause Troubleshooting ProcedureData plate within +/- 10% Brew cycle will not start No waterProblem Possible Cause Power Possible Cause Limit ThermostatTank Heaters Triac ProblemProblem Possible Cause Troubleshooting Procedures Water temperature Consistently high or low beverage Brew Volume adjustmentLevel in server For each brew cycleWeak beverage Incorrect Recipe Tank Heaters Remove and clean lime off tankAge, preinfusion, or pulse brew TionsDual SH with Smart Funnel DBC Schematic Wiring DiagramSchematic Wiring Diagram Dual SH DBC W/SMART Funnel Limit Thermostat MT1

S/N DUAL068000 specifications

The Bunn S/N DUAL068000 is a versatile and high-performance commercial coffee brewer designed for those who demand quality and efficiency in their coffee-making operations. This brewer is part of Bunn’s DUAL series, known for its innovative technology and robust construction, making it a favored choice among coffee shops, restaurants, and offices.

One of the standout features of the DUAL068000 is its dual brewing capability. This allows users to brew two different types of coffee simultaneously, ensuring a wide range of flavors and options for customers. The unit is equipped with two independent brewing chambers, each capable of producing a batch of coffee in a matter of minutes, which is ideal for high-volume settings.

The DUAL068000 utilizes Bunn’s state-of-the-art brewing technology, including its patented "Duo-Temp" brewing system. This technology ensures that water is heated to the optimal temperature, generally between 195°F and 205°F, for extracting the best flavors from coffee grounds. Furthermore, the unit features a precision digital control system with programmable settings, allowing users to fine-tune brew times and temperatures for consistent quality.

An innovative characteristic of the DUAL068000 is its energy efficiency. The brewer incorporates an energy-saving mode, reducing power consumption during off-peak hours without sacrificing performance when needed. This makes the brewer not only cost-effective but also environmentally friendly, aligning with the growing trend towards sustainability in the food and beverage industry.

In terms of construction, the Bunn S/N DUAL068000 boasts a durable stainless steel design, ensuring longevity and resistance to wear and tear. It is also designed with easy access to components for maintenance, making it convenient for operators to clean and service the machine as necessary.

Other notable features include an integrated hot water faucet for tea and instant beverages, the capability to brew into various container sizes, and a large reservoir that minimizes refill frequency.

In conclusion, the Bunn S/N DUAL068000 is an exemplary commercial coffee brewer that combines advanced technology, durable construction, and user-friendly features. Its dual brewing capability and energy-saving design make it a top choice for establishments looking to enhance their coffee offerings while maintaining efficiency and quality. With this brewer, businesses can cater to a diverse array of customer preferences, making it an invaluable asset in any beverage service environment.