Bunn ITB/ITCB, ICB/TWIN manual ICB Twin Tank Heaters

Page 17

TANK HEATERS

2268W

1425W

Large

Small

Dia.

Dia.

 

FIG. 17-1 ICB TWIN TANK HEATERS

Location:

The tank heaters are located inside the tank and secured to the tank bottom.

Test Procedures:

1.With a voltmeter, check voltage across the white wire (120V Models) or red wire (120/208-240V Models) from the terminal block and black wire from the control board. Connect brewer to the power source. The indication must be 120 volts ac for two wire 120 volt models or 208-240 volts ac for three wire 120/208-240 volt models (during a heating cycle).

2.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #3.

If voltage is not present as described, refer to the Wir- ing Diagrams and check wiring harness.

3.Disconnect the wires from the tank heater termi- nals.

4.Check resistance value across tank heater terminals and compare to chart.

If resistance is present as described, reconnect the wires, the tank heater is ok.

If resistance is not present as described, replace the tank heater.

FIG. 17-2 DV TANK HEATERS

HEATER

RESISTANCE

1425W-120V

9.5-11.0

3500W-240V

15.1-17.6

1680W-120V

7.9-9.2

1800W-120V

7.4-8.7

2268W-120V

5.9-6.9

3000W-208V

12.9-15.1

3000W-240V

17.9-20.7

3500W-200V

10.5-12.2

TERMINAL TO SHEATH - INFINITE (OPEN)

NOTE- If any resistance is read between sheath and either terminal, remove and inspect heater for cracks in the sheath.

Removal and Replacement:

1.Remove the top cover and front access panel as previously described.

2.Drain water from the tank.

3.Disconnect all the hoses from the tank.

4.Remove the temperature probe from the grommet in the tank lid.

5.Remove the level probe from it's grommet.

6.Disconnect the green wire from the tank lid.

7.Disconnect the wires from tank heater terminals.

8.Remove the nuts securing the tank lid to the tank.

9.Remove the hex nuts securing the tank heater to the bottom of the tank. Remove tank heater(s) with gaskets and discard.

10.Install new tank heater(s) with gaskets to the bot- tom of the tank and secure with two hex nuts.

11.Install tank lid and secure with nuts.

12.Reconnect the wires to tank heater terminals.

17

42461 0911809

 

Image 17
Contents ITB/ITCB ICB/TWIN BUNN-O-MATIC Commercial Product Warranty Introduction Control Boards TroubleshootingRefill Circuit Problem TroubleshootingProbable Cause RemedyHeating Circuit Problem Probable Cause Remedy Brewing Circuit Problem Probable Cause Remedy Problem Probable Cause Remedy Troubleshooting Brewing CircuitMessage Probable Cause Remedy DiagnosticsICB Component Access Component AccessControl Board Membrane Switch Continuity Membrane SwitchExploded View Early Brew ValveLate Model Brew Valve Brew Valve Late ModelsRefill Valves DisassemblyEarly Itcb Refill Valves Early ICBICB Twin Tank Heaters Tank HeatersLimit Thermostats Limit ThermostatTesting Temperature Probe Temperature ProbeCalibrate Temp Probe CalibrationTest Procedure Voltage Selector SwitchTest Procedure Removal and Replacement Power SwitchSchematic Wiring Diagram iTCBA, iTCBB Schematic Wiring Diagram With Factory Sweetener Schematic Wiring Diagram ICB-DV Schematic Wiring Diagram ICB Twin Schematic Wiring Diagram iCBA, iCBB Schematic Wiring Diagram ICB Twin 230V Chassis Ground Term Schematic Wiring Diagram ITB