DIAGNOSTICS
MESSAGE
PROBABLE CAUSE |
| REMEDY |
Temperature Too Low
1.Water temperature in the tank does not meet the ready tempera- ture.
A)Wait for the brewer to heat to the proper temperature.
B)Disable the BREW LOCKOUT function. Refer to programming section for procedure.
Heating Time Too Long
Fill Time Too Long
Temp Sensor Out Of Range, Check For Bad Connections
Temp Sensor Out Of Range, Check Wire For Shorts
1. | Tank Heater failure. |
| Replace or repair as needed | |
2. | Control Board/Thermistor fail- | Replace or repair as needed | ||
ure |
|
|
| |
1. | Water shut off to brewer |
| Check water supply | |
2. | Supply line too small or ob- | Replace or repair as needed | ||
structed |
|
|
| |
3. | Inlet Solenoid failure |
| Replace or repair as needed | |
4. | Control Board Failure |
| Replace or repair as needed | |
5. | ON/OFF switch is OFF |
| Turn switch ON | |
1. | Temperature | Sensor | Probe | Replace or repair as needed |
open |
|
|
| |
1. | Temperature | Sensor | Probe | Replace or repair as needed |
wire(s) shorted |
|
|
|
9 | 42461 0911809 |
|