Bunn Troubleshooting and Brewing Circuit Guide for Coffee Makers

Page 8

TROUBLESHOOTING (cont.)

 

 

 

BREWING CIRCUIT (cont.)

 

 

 

PROBLEM

 

PROBABLE CAUSE

 

REMEDY

Dripping from sprayhead

1. Lime build up

 

Inspect the tank assembly for ex-

 

 

 

 

cessive lime deposits. Delime as

 

 

 

 

required.

 

 

2. Dispense valve

 

Check/replace

Weak beverage

1. Sprayhead

 

A clean sprayhead must be used for

 

 

 

 

proper extraction.

 

 

2. Water temperature

 

Place an empty brew funnel on an

 

 

 

 

empty decanter beneath the spray-

 

 

 

 

head. Initiate brew cycle and check

 

 

 

 

the water temperature immediately

 

 

 

 

below the sprayhead with a ther-

 

 

 

 

mometer. The reading must not be

 

 

 

 

less than 195°F (91°C). Adjust the

 

 

 

 

temperature setting to increase the

 

 

 

 

water temperature. Refer to Initial

 

 

 

 

Set-up instructions.

 

 

 

 

BUNN® paper filters must be used

 

 

3. Filter type

 

for proper extraction.

 

 

 

 

A fine drip or grind must be used

 

 

4. Coffee grind

 

for proper extraction.

 

 

 

 

The BUNN® paper filter must be

 

 

5. Funnel loading

 

centered in the funnel and the bed

 

 

 

 

of grounds leveled by shaking

 

 

 

 

gently.

Dry coffee grounds remain in the

1. Sprayhead

 

Make sure sprayhead is present and

funnel

 

 

holes are clear and unobstructed.

 

 

 

 

The BUNN® paper filter must be

 

 

2. Funnel loading

 

centered in the funnel and the bed

 

 

 

 

of grounds leveled by shaking

 

 

 

 

gently.

Low beverage serving tempera-

1. Thermal server/airpot not pre-

 

Preheat server

ture

heated before brew cycle

 

 

8

42461 0911809

 

Image 8
Contents ITB/ITCB ICB/TWIN BUNN-O-MATIC Commercial Product Warranty Introduction Troubleshooting Control BoardsTroubleshooting Refill Circuit ProblemProbable Cause RemedyHeating Circuit Problem Probable Cause Remedy Brewing Circuit Problem Probable Cause Remedy Troubleshooting Brewing Circuit Problem Probable Cause RemedyDiagnostics Message Probable Cause RemedyComponent Access ICB Component AccessControl Board Membrane Switch Membrane Switch ContinuityEarly Brew Valve Exploded ViewBrew Valve Late Models Late Model Brew ValveDisassembly Refill ValvesRefill Valves Early ICB Early ItcbTank Heaters ICB Twin Tank HeatersLimit Thermostat Limit ThermostatsTemperature Probe Testing Temperature ProbeCalibration Calibrate Temp ProbeVoltage Selector Switch Test ProcedurePower Switch Test Procedure Removal and ReplacementSchematic Wiring Diagram iTCBA, iTCBB Schematic Wiring Diagram With Factory Sweetener Schematic Wiring Diagram ICB-DV Schematic Wiring Diagram ICB Twin Schematic Wiring Diagram iCBA, iCBB Schematic Wiring Diagram ICB Twin 230V Chassis Ground Term Schematic Wiring Diagram ITB