1.Turn the fryer off. Allow the shortening to cool to 130“ F/54“ C.

WARNING

Hot shortening may cause serious injury.

2.Turn the EZ Melt off. Make sure that both the HEAT and PUMP switches are in the OFF position.

3.Make sure that the top of the cube melter is exposed.

 

If

Side of

shortening

level is

Cube

Melter.

here or

 

below

Bottom of

drain fryer.

kettle.

 

Figure 2-6. When to Drain the Fryer.

 

 

If

 

Side of

 

shortening

 

cube

 

melter.

level is here

 

 

or below

 

Bottom of

drain fryer.

 

 

 

kettle.

 

 

 

 

 

 

 

Figure 2-6A. (EZ-34 ONLY) When to Drain

the Fryer.

WARNING

When you begin to drain the fryer, the

shortening in the EZ Melt must be shallow enough for the top of the cube melter to be exposed. If the shortening is deeper it might overflow when you drain the fryer, thus causing burns or other serious injury.

4.Position the shortening filter assembly on the EZ Melt kettle. The edge of the kettle has one or two sets of holes in it. Use the set of holes that is farther from the heater head. When two of the filter frame’s pins rest in these holes, the filter assembly rests horizontally on the end of the kettle. (See Figure 2-7.)

Figure 2-7. Positioning the Filter Assembly

for Filtering.

5.Disconnect the supply hose from the hose connector. Hold the two ends of the hose up so shortening does not drip out. Hang hose vertically over a pan so the shortening will drip into the pan.

6.Attach the rinsing hose securely to the hose connector. (See Figure 2-8.)

Belshaw Bros., Inc. š 1750 22nd Ave. S. š Seattle, WA 98144 š Phone 206-322-5474 š Fax 206-322- 5425

EZ Melt Model EZ18, EZ24, EZ34

MN-1316EN

7

Image 15
Contents Models EZ18, EZ24, AND EZ34 Operator’s Manual EZ MeltFill and Filter Page EQUIPMENT RECORD Page Troubleshooting ContentsInstallation CleaningFigures Preface Page heater head 1Installationfilter assembly handlehose connector Heating element kettle Reset button Heat switch with pilot lightPump switch with pilot light Figure 1-4.Heater head Bleeder Pickup tubeTo avoid electrocuting yourself or damaging Melting and Filling 2Operation7.Turn the pump on using the PUMP switch Filtering a.Allow the filter assembly to cool to the touch d.Put the filter assembly back on the EZ Melt Cleaning3 Do not touch the heating element! It is very Troubleshooting4 THE PUMP MOTOR WILL NOT RUN Possible CausesWhat To Do This page has been left blank intentionally Parts Lists ITEM QTY. DESCRIPTION BILL OF MATERIALDESCRIPTION FASTENERSFIGURE 5-1 EZ18-2000SHORTENING MELTER ASSEMBLY DESCRIPTION FIGURE 5-2 EZ18-2001SHORTENING MELTER ASSEMBLY DESCRIPTION FIGURE 5-3 EZ24-2000SHORTENING MELTER ASSEMBLY DESCRIPTION FIGURE 5-4 EZ24-2001SHORTENING MELTER ASSEMBLY DESCRIPTION FIGURE 5-5 EZ34-2000SHORTENING MELTER ASSEMBLY DESCRIPTION FIGURE 5-6 EZ34-2001SHORTENING MELTER ASSEMBLY FIGURE 5-7 EZ24/34-1000HEATER HEAD ASSEMBLY PARTS LIST 5-7 EZ24/34-1000HEATER HEAD ASSEMBLY Wiring Diagrams EZ18-4002120V, 50/60 Hz, 1 PhEZ18-4003208/240V, 50/60 Hz, 1 Ph MN-1316EN EZ Melt Model EZ18, EZ24, EZ34EZ Melt Model EZ18, EZ24, EZ34 MN-1316EN