Cleaning3

Clean the EZ Melt after every use. Follow these steps:

1.Turn on the heat and the pump.

2.Press the foot pedal to pump shortening out of the EZ Melt and into a metal container or fryer kettle.

3.When you cannot pump any more shortening out of the EZ Melt, release the foot pedal. Turn off the heat and the pump.

4.Disconnect the EZ Melt from the power source.

5.Allow the shortening in the EZ Melt kettle to cool to 115“ F/46“ C.

WARNING

Thoroughly clean and dry the floor if shortening, water, or other materials are spilled. Materials spilled on the floor may cause serious injury and loss of life.

7.Remove the cube melter.

8.Loosen the two fasteners at the back of the heater head, lift it off the kettle and place it in a clean safe place. The foot valve and cord will unsnap from the frame. See Figure 3-1.

WARNING

Hot shortening can cause serious injury.

6.Clean the EZ Melt filter. Follow these steps:

a.Allow the filter assembly to cool to the touch.

b.Lift off the filter assembly, holding it by the frame.

c.Invert the filter assembly over a sink or garbage can and shake the sediment off of it.

d.Unsnap the filter to remove it from the filter frame.

e.Rinse the remaining shortening and

crumbs off of the filter.

Figure 3-1. Removing the Heater Head.

 

(Place heater head as shown above so no

 

damage is done to the element.)

Belshaw Bros., Inc. š 1750 22nd Ave. S. š Seattle, WA 98144 š Phone 206-322-5474 š Fax 206-322- 5425

10

MN-1316EN

EZ Melt Model EZ18, EZ24, EZ34

Image 18
Contents Models EZ18, EZ24, AND EZ34 Operator’s Manual EZ MeltFill and Filter Page EQUIPMENT RECORD Page Cleaning ContentsInstallation TroubleshootingFigures Preface Page handle 1Installationfilter assembly heater headhose connector Figure 1-4.Heater head Bleeder Pickup tube Reset button Heat switch with pilot lightPump switch with pilot light Heating element kettleTo avoid electrocuting yourself or damaging 2Operation Melting and Filling7.Turn the pump on using the PUMP switch Filtering a.Allow the filter assembly to cool to the touch d.Put the filter assembly back on the EZ Melt Cleaning3 Do not touch the heating element! It is very Troubleshooting4 THE PUMP MOTOR WILL NOT RUN Possible CausesWhat To Do This page has been left blank intentionally Parts Lists FASTENERS BILL OF MATERIALDESCRIPTION ITEM QTY. DESCRIPTIONFIGURE 5-1 EZ18-2000SHORTENING MELTER ASSEMBLY BILL OF MATERIAL FIGURE 5-2 EZ18-2001SHORTENING MELTER ASSEMBLY BILL OF MATERIAL FIGURE 5-3 EZ24-2000SHORTENING MELTER ASSEMBLY BILL OF MATERIAL FIGURE 5-4 EZ24-2001SHORTENING MELTER ASSEMBLY BILL OF MATERIAL FIGURE 5-5 EZ34-2000SHORTENING MELTER ASSEMBLY BILL OF MATERIAL FIGURE 5-6 EZ34-2001SHORTENING MELTER ASSEMBLY FIGURE 5-7 EZ24/34-1000HEATER HEAD ASSEMBLY PARTS LIST 5-7 EZ24/34-1000HEATER HEAD ASSEMBLY Wiring Diagrams EZ18-4002120V, 50/60 Hz, 1 PhEZ18-4003208/240V, 50/60 Hz, 1 Ph EZ Melt Model EZ18, EZ24, EZ34 MN-1316ENMN-1316EN EZ Melt Model EZ18, EZ24, EZ34