THE SHORTENING DOES NOT FLOW FREELY THROUGH THE FILTER SYSTEM
Possible Causes |
| What To Do | ||
|
|
|
|
|
The hose is crimped. |
| Straighten the hose. | ||
|
|
|
| |
|
| WARNING |
|
|
|
|
|
|
|
|
| To avoid being burned, before doing any of the |
|
|
|
| following, turn off the EZ Melt and allow the |
|
|
|
| shortening to cool. |
|
|
|
|
|
|
|
The hose is clogged with shortening. |
| Soak the hose in warm water to help release the | ||
| clogged shortening. Hang it up and let it dry | |||
| before you use it again. | |||
|
|
| ||
The drain tube is clogged with solid shortening. | Remove the drain tube and soak it in warm water | |||
| to help release the clogged shortening. | |||
|
|
| ||
The pickup tube is clogged with residue. | Remove the pickup tube and clean it. | |||
|
|
|
|
|
THE PUMP MOTOR WILL NOT RUN |
|
|
|
|
|
|
|
|
|
Possible Causes |
| What To Do | ||
|
| |||
The connection of the power cord to the power | Make sure the power cord is fully plugged in to a | |||
source is faulty. | proper power source. | |||
|
|
| ||
The circuit breaker has been tripped. |
| Press the reset button. | ||
| If the problem persists, consult your Belshaw | |||
| dealer, or call Belshaw. | |||
|
|
|
|
|
Belshaw Bros., Inc. 1750 22nd Ave. S. Seattle, WA 98144 Phone
EZ Melt Model EZ18, EZ24, EZ34 | 13 |