MP 101, cont’d
Remote Control
The wiring and control options described below pertain to all models in the MP 101 series.
Remote connector wiring
As shown below, Pin 1 is 10 VDC reference voltage. Pin 2 is volume control DC voltage; range is 0 to 10 V, where 0 V is mute and 10 V provides maximum volume. Pin 3 is ground.
NAll nominal levels are at ±10%.
MAX
10K
MIN
REMOTE
1 | 2 | 3 |
10V
VOL/MUTE
1
2K
2
MUTE
3
GND
MP 101 |
| LINE | ||
MIC TO LINE |
| OUTPUT | ||
PREAMPLIFIER |
|
| ||
POWER |
|
| ||
12V |
| MIC |
| |
0.5A | MAX | REMOTE | ||
INPUT | ||||
|
|
10V |
VOL/MUTE
Remote control options
The MP 101 has three remote control options:
1.The Extron VCM 100 volume/mute controller and
VC 50 volume controller use a 10 k ohm potentiometer as the main method for controlling volume levels.
The VCM 100 includes an illuminated Mute button and operates in sync with the MP 101 AAP.
2.The Extron
3.Generic volume/mute controllers are standard 10 k ohm potentiometers.