Extron electronic MP 101, cont’d Remote Control, Remote connector wiring, 10 MP 101 Series MP

Page 18

MP 101, cont’d

Remote Control

The wiring and control options described below pertain to all models in the MP 101 series.

Remote connector wiring

As shown below, Pin 1 is 10 VDC reference voltage. Pin 2 is volume control DC voltage; range is 0 to 10 V, where 0 V is mute and 10 V provides maximum volume. Pin 3 is ground.

NAll nominal levels are at ±10%.

MAX

10K

MIN

REMOTE

1

2

3

10V

VOL/MUTE

1

2K

2

MUTE

3

GND

MP 101

 

LINE

MIC TO LINE

 

OUTPUT

PREAMPLIFIER

 

 

POWER

 

 

12V

 

MIC

 

0.5A

MAX

REMOTE

INPUT

 

 

10V

VOL/MUTE

Remote control options

The MP 101 has three remote control options:

1.The Extron VCM 100 volume/mute controller and

VC 50 volume controller use a 10 k ohm potentiometer as the main method for controlling volume levels.

The VCM 100 includes an illuminated Mute button and operates in sync with the MP 101 AAP.

2.The Extron MLA-VC10converts RS-232 serial command to 0~10 volt variable DC for volume control.

3.Generic volume/mute controllers are standard 10 k ohm potentiometers.

2-10 MP 101 Series • MP 101

Image 18
Contents MP 101 Series Microphone to Line PreamplifiersPrecautions FCC Class a Notice Table of Contents Chapter Five Architectural Installation One IntroductionAbout the MP 101, MP 101 AAP, MP 101 D FeaturesIntroduction About this Manual MP 101 Series IntroductionMP 101 Series Introduction Two Rear Panel Features Power inputMP 101 Series MP Mic input microphone level MP 101 Series MP 101Remote connection Front Panel FeaturesMP 101, cont’d Audio output line levelMounting the MP Tabletop useRack installation Back of the rack installation Furniture mounting Adjusting the MP Remote control options MP 101, cont’d Remote ControlRemote connector wiring 10 MP 101 Series MPThree MP 101 AAPMP 101 AAP MP 101 Series MP 101 AAPMLP 101 AAP Adjusting the MP 101 AAP MP 101 AAP, cont’dMounting the MP 101 AAP Remote Remote control options Four MP 101 DMP 101 D About the MP 101 D MP 101 Series MP 101 DAudio output line level MP 101 D, cont’d Front Panel Features Adjusting the MP 101 D Mounting the MP 101 DMP 101 D, cont’d Extron MP 101 DRemote Control Architectural Installation FiveArchitectural Installation Installation Instructions Preparing the Site and Installing the Wall BoxMP 101 Series Architectural Installation MP 101 Series Architectural Installation Architectural Installation, cont’d Specifications, Part Numbers, and Accessories AAppendix aAudio input Specifications, Part Numbers, and AccessoriesAudio Audio outputGeneral UL, CUL Included Parts Included parts Part numberOptional Accessories Accessories Part numberDimensions and Template for the MP 101 D AppendixBBDimensions and Template MP 101 Series Dimensions and Template for the MP 101 DMP 101 D TemplateExtron’s Warranty USA, Canada, South America Japan Central AmericaExtron Electronics. All rights reserved