Extron electronic MP 101 user manual General

Page 39

General

External power supply

100 VAC to 240 VAC, 50/60 Hz, external,

 

autoswitchable; to 12 VDC, 1 A, regulated

Power input requirements

12 VDC, 0.3 A

 

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

10% to 90%, noncondensing

 

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

10% to 90%, noncondensing

 

Rack mount

 

 

MP 101

Yes, with optional 1U rack shelf,

 

 

part #60-190-01 or 60-604-01; or

 

 

VersaTools® rack shelf, part #60-190-20 or

 

60-604-20; or back of the rack mount kit,

 

70-367-01. It is also furniture-mountable

 

with optional under-desk mounting kit

 

#70-212-01, or it can be attached to a

 

 

projector mount with optional kit

 

 

#70-217-01.

 

MP 101 AAP

Yes, with optional faceplate or frame

 

MP 101 D

No, but wall or furniture mountable in a

 

Decora-style opening

 

Enclosure type

Metal

 

Enclosure dimensions

 

 

MP 101

1.7" H x 2.2" W x 3.0" D

 

 

(1U high, one-eighth rack wide)

 

 

4.3 cm H x 5.6 cm W x 7.6 cm D

 

 

(Depth excludes connectors.)

 

MP 101 AAP

 

 

Faceplate

1.4" H x 3.5" W x 0.1" D

 

 

(3.6 cm H x 8.9 cm W x 0.3 cm D)

 

 

(double space high AAP plate)

 

Device

1.1" H x 2.75" W x 1.8" D

 

 

(2.8 cm H x 7.0 cm W x 4.6 cm D)

 

 

(Depth excludes connectors.)

 

MP 101 D

 

 

Faceplate

2.6" H* x 1.3" W x 0.1" D

 

 

(6.6 cm H* x 3.3 cm W x 0.3 cm D)

 

 

(Fits the opening in a 1 gang Decora

 

 

faceplate. *Height is 3.8” [9.7 cm]

 

 

including mounting tabs.)

 

Device

2.75" H x 1.1" W x 1.8" D

 

 

(7.0 cm H x 2.8 cm W x 4.6 cm D)

 

 

(Depth excludes connectors.)

 

Product weight

0.3 lbs (0.1 kg)

 

MP 101 Series • Specifications, Part Numbers, and Accessories

A-3

Image 39
Contents Microphone to Line Preamplifiers MP 101 SeriesPrecautions FCC Class a Notice Table of Contents Chapter Five Architectural Installation Introduction OneMP 101 Series Introduction FeaturesIntroduction About this Manual About the MP 101, MP 101 AAP, MP 101 DMP 101 Series Introduction Two Rear Panel Features Power inputMP 101 Series MP MP 101 Series MP 101 Mic input microphone levelAudio output line level Front Panel FeaturesMP 101, cont’d Remote connectionTabletop use Mounting the MPRack installation Back of the rack installation Furniture mounting Adjusting the MP 10 MP 101 Series MP MP 101, cont’d Remote ControlRemote connector wiring Remote control optionsMP 101 AAP ThreeMP 101 Series MP 101 AAP MP 101 AAPMLP 101 AAP MP 101 AAP, cont’d Adjusting the MP 101 AAPMounting the MP 101 AAP Remote Remote control options MP 101 D FourMP 101 Series MP 101 D MP 101 D About the MP 101 DAudio output line level MP 101 D, cont’d Front Panel Features Mounting the MP 101 D Adjusting the MP 101 DExtron MP 101 D MP 101 D, cont’dRemote Control Five Architectural InstallationArchitectural Installation Installation Instructions Preparing the Site and Installing the Wall BoxMP 101 Series Architectural Installation MP 101 Series Architectural Installation Architectural Installation, cont’d AAppendix a Specifications, Part Numbers, and AccessoriesAudio output Specifications, Part Numbers, and AccessoriesAudio Audio inputGeneral UL, CUL Included parts Part number Included PartsAccessories Part number Optional AccessoriesAppendixBB Dimensions and Template for the MP 101 DMP 101 Series Dimensions and Template for the MP 101 D Dimensions and TemplateTemplate MP 101 DUSA, Canada, South America Japan Central America Extron’s WarrantyExtron Electronics. All rights reserved