C. Location

CAUTION

1.This icemaker is not intended for outdoor use. Normal operating ambient temperature should be within 45°F to 100°F (7°C to 38°C); Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect icemaker performance.

2.This icemaker will not work at sub-freezing temperatures. To prevent damage to the water supply line, drain the icemaker if the air temperature is going to go below 32°F (0°C). See "III.C. Preparing the Icemaker for Long Storage."

For best operating results:

The icemaker should not be located next to ovens, grills, or other high heat producing equipment.

The location should provide a firm and level foundation for the equipment.

Allow 6" (15 cm) clearance at rear, sides, and top for proper air circulation and ease of maintenance and/or service should they be required.

D.Setup

1)Unpack the storage bin, and attach the 4 adjustable legs provided (bin accessory) to the bottom of the storage bin.

2)Position the storage bin in the selected permanent location.

3)Place the icemaker on top of the storage bin.

4)Secure the icemaker to the storage bin

using the 2 mounting brackets and the bolts provided. See Fig. 2.

5) Level the icemaker and storage bin in both

Icemaker

the left-to-right and fronttorear directions.

 

Adjust the storage bin legs to make the

 

icemaker level.

 

6) Replace the panels in their correct positions.

Bin

Mounting

Brackets

Bolts

Fig. 2

12

Image 12
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Important Safety Information Specifications Nameplate Rating KM-650MAH air-cooledKM-650MWH water-cooled MAX. Hacr Breakerusa only AmpsKM-650MRH remote air-cooled Dimensions / Connections KM-650MAHKM-650MWH KM-650MRH II. Installation and Operating Instructions Checks Before InstallationHow to Remove Panels See Fig Setup LocationElectrical Connection For All ModelsAdditional Warnings for Remote Air-Cooled Model Installation of Remote Condenser Unit Checks Before InstallationLocation Setup Line SetField Fabricated Line Set Installation Ester Electrical Connection Stacking Remote Condenser Units Water Supply and Drain Connections See , 12, orKM-650MAH and KM-650MRH IcemakerWater-Cooled Condenser Connection to an Open Drain SystemKM-650MWH Final Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Stainless Steel ExteriorStorage Bin and Scoop Air Filters air-cooled modelPreparing the Icemaker for Long Storage Remove the water from the icemaker water supply lineDrain the water tank Page Hoshizaki AMERICA, INC