2. Water-Cooled Condenser
a) Connection to an Open Drain System
•Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD copper tubing is recommended for the condenser water supply line.
•A condenser water supply line
•Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for the condenser drain line.
•In some areas, a back flow preventer may be required in the cooling water circuit.
Icemaker Water
Supply Inlet
1/2" FPT
Condenser Water
Supply Inlet
1/2" FPT
Icemaker
Icemaker Water Supply Line
Condenser
Drain Outlet
3/8" FPT
Condensation
Drain Outlet
3/8" OD Stainless
Tube
Icemaker
Drain Outlet
3/4" FPT
Bin
Bin Drain Outlet 3/4" FPT
Condenser Water Supply Line
Icemaker Water Supply Line
Drain Valve
Condenser Water Supply Line Drain Valve
Separate piping to approved drain. Leave a
Floor Drain
Fig. 12 | |
| Connection to an Open Drain System |
22