Hoshizaki KM-650MAH instruction manual Electrical Connection

Page 18

5. Electrical Connection

WARNING

1.Electrical connection must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or extensive damage to equipment.

2.THIS UNIT MUST BE GROUNDED. Be sure to install a proper ground from the icemaker to the remote condenser unit. Use wire of an appropriate gage and outdoor rating. Failure to properly ground this unit could result in death or serious injury.

3.The remote condenser unit must be connected to the fan motor junction box on the icemaker. Use wire of an appropriate gage and outdoor rating. Do not connect the remote condenser leads to an external power source.

4.To reduce the risk of electric shock, make all remote condenser unit connections before connecting the icemaker power supply.

5.On remote air-cooled model, the icemaker should have power for a minimum of 4 hours prior to startup to prevent compressor damage.

Usually an electrical permit and services of a licensed electrician are required.

The opening for the power supply connection is 7/8" DIA to fit a 1/2" trade size conduit.

1)Remove the louver panel. See Fig. 9.

2)Remove the junction box cover on the remote condenser unit. Remove the fan motor junction box cover on the icemaker.

3)Install a ground wire from the icemaker to the remote condenser unit. Use wire of an appropriate gage and outdoor rating.

4)Connect the fan motor leads in the junction box of the remote condenser unit to the fan motor leads in the fan motor junction box of the icemaker. Use wire of an appropriate gage and outdoor rating.

5)Replace the junction box covers and the louver panel in their correct positions.

Remote Condenser Unit

Screws

Junction Box

Cover

Louver Panel

Icemaker

Fan Motor Junction Box Cover

Screw

Fig. 9

18

Image 18
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Important Safety Information Specifications Nameplate Rating KM-650MAH air-cooledKM-650MWH water-cooled MAX. Hacr Breakerusa only AmpsKM-650MRH remote air-cooled Dimensions / Connections KM-650MAHKM-650MWH KM-650MRH II. Installation and Operating Instructions Checks Before InstallationHow to Remove Panels See Fig Setup LocationElectrical Connection For All ModelsAdditional Warnings for Remote Air-Cooled Model Installation of Remote Condenser Unit Checks Before InstallationLocation Setup Line SetField Fabricated Line Set Installation Ester Electrical Connection Stacking Remote Condenser Units Water Supply and Drain Connections See , 12, orKM-650MAH and KM-650MRH IcemakerWater-Cooled Condenser Connection to an Open Drain SystemKM-650MWH Final Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Storage Bin and Scoop MaintenanceStainless Steel Exterior Air Filters air-cooled modelPreparing the Icemaker for Long Storage Remove the water from the icemaker water supply lineDrain the water tank Page Hoshizaki AMERICA, INC