G. Water Supply and Drain Connections

See Fig. 11, 12, or 13

WARNING

1.Water supply and drain connections must be installed in accordance with applicable national, state, and local regulations.

2.Normal operating water temperature should be within 45°F to 90°F (7°C to 32°C). Operation of the icemaker, for extended periods, outside of this normal temperature range may affect icemaker performance.

3.To prevent damage to equipment, do not operate the icemaker when the water supply is off, or if the pressure is below 10 PSIG. Do not run the icemaker until the proper water pressure is reached.

A plumbing permit and services of a licensed plumber may be required in some areas.

External filters, strainers, or softeners may be required depending on water quality. Contact your local Hoshizaki distributor for recommendations.

Water supply pressure should be a minimum of 10 PSIG and a maximum of 113 PSIG. If the pressure exceeds 113 PSIG, the use of a pressure reducing valve is required.

The icemaker and condensation drain line(s), storage bin drain line, and watercooled condenser drain line (if applicable) must be run separately.

Drain lines must have 1/4" fall per foot (2 cm per 1 m) on horizontal runs to get a good flow. A vented tee connection is also required for proper flow.

Drain lines should not be piped directly to the sewer system. An air gap of a minimum of 2 vertical inches (5 cm) should be between the end of the drain pipes from the icemaker and condensation drain, storage bin, and water-cooled condenser (if applicable) and the floor drain.

20

Image 20
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Important Safety Information Specifications Nameplate Rating KM-650MAH air-cooledKM-650MWH water-cooled MAX. Hacr Breakerusa only AmpsKM-650MRH remote air-cooled Dimensions / Connections KM-650MAHKM-650MWH KM-650MRH How to Remove Panels See Fig II. Installation and Operating InstructionsChecks Before Installation Setup LocationAdditional Warnings for Remote Air-Cooled Model Electrical ConnectionFor All Models Location Installation of Remote Condenser UnitChecks Before Installation Setup Line SetField Fabricated Line Set Installation Ester Electrical Connection Stacking Remote Condenser Units Water Supply and Drain Connections See , 12, orKM-650MAH and KM-650MRH IcemakerWater-Cooled Condenser Connection to an Open Drain SystemKM-650MWH Final Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Stainless Steel ExteriorStorage Bin and Scoop Air Filters air-cooled modelDrain the water tank Preparing the Icemaker for Long StorageRemove the water from the icemaker water supply line Page Hoshizaki AMERICA, INC