Hoshizaki KM-650MAH instruction manual Important Safety Information

Page 4

Important Safety Information

Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit.

WARNING Indicates a hazardous situation which could result in death or serious injury.

CAUTION

Indicates a situation which could result in damage to the unit.

IMPORTANT Indicates important information about the use and care of the unit.

WARNING

This icemaker should be destined only to the use for which it has been expressly conceived. Any other use should be considered improper and therefore dangerous. The manufacturer cannot be held responsible for eventual damage caused by improper, incorrect, and unreasonable use.

To reduce the risk of death, electric shock, serious injury, or fire, follow basic precautions including the following:

Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or extensive damage to equipment.

This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuses, or damage to existing wiring. This could lead to heat generation or fire.

THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could result in death or serious injury.

This unit should be disassembled or repaired only by qualified service personnel to reduce the risk of electric shock, injury, or fire.

Do not make any alterations to the unit. Alterations could result in electric shock, injury, fire, or damage to the unit.

Image 4
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Important Safety Information Specifications Nameplate Rating KM-650MAH air-cooledKM-650MWH water-cooled MAX. Hacr Breakerusa only AmpsKM-650MRH remote air-cooled Dimensions / Connections KM-650MAHKM-650MWH KM-650MRH Checks Before Installation II. Installation and Operating InstructionsHow to Remove Panels See Fig Setup LocationFor All Models Electrical ConnectionAdditional Warnings for Remote Air-Cooled Model Checks Before Installation Installation of Remote Condenser UnitLocation Setup Line SetField Fabricated Line Set Installation Ester Electrical Connection Stacking Remote Condenser Units Water Supply and Drain Connections See , 12, orKM-650MAH and KM-650MRH IcemakerWater-Cooled Condenser Connection to an Open Drain SystemKM-650MWH Final Checklist Startup III. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Stainless Steel ExteriorStorage Bin and Scoop Air Filters air-cooled modelRemove the water from the icemaker water supply line Preparing the Icemaker for Long StorageDrain the water tank Page Hoshizaki AMERICA, INC